ABB AF09-40-00-13

Image Disclaimers Message
ABB AF09-40-00-13
ABB AF09-40-00-13
Part #:AF09-40-00-13
SKU #: 2278541
Key Features
Part #:AF09-40-00-13
SKU #: 2278541
Brand: ABB
Coil Power Rating: 7-1/2 hp
Coil Voltage: 100 VAC, 250 VDC
Contact Configuration: 4NO
Contact type: Non-Reversing
Dimensions: 86 mm H x 45 mm W x 77 mm D
- AF contactors can manage large control voltage variations one coil can be used for different control voltages used worldwide without any coil change
- AF series contactor coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 24 to 500 VAC
- Main poles and auxiliary contact blocks 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1
- 6 kV rated impulse withstand voltage
- 600/690 VAC rated insulation voltage
- 3000 m maximum operating altitude permissible
- 0.75 hp at 120 VAC, 1.5 hp at 240 VAC 1-phase 2 hp at 200/208 VAC, 2 hp at 220/240 VAC, 5 hp at 440/480 VAC, 7.5 hp at 550/600 VAC 3-phase power rating
- AF contactors can manage large control voltage variations one coil can be used for different control voltages used worldwide without any coil change
- AF series contactor coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 24 to 500 VAC
- Main poles and auxiliary contact blocks 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1
- 6 kV rated impulse withstand voltage
- 600/690 VAC rated insulation voltage
- 3000 m maximum operating altitude permissible
- 0.75 hp at 120 VAC, 1.5 hp at 240 VAC 1-phase 2 hp at 200/208 VAC, 2 hp at 220/240 VAC, 5 hp at 440/480 VAC, 7.5 hp at 550/600 VAC 3-phase power rating
ABB AF09-40-00-13
Additional Description: ABB -AF09-40-00-13 AF09 4P CONTR, 100-250VAC/DC
Catalog Description: AF09 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operate