ABB AF09-30-01-13 IEC Contactor

2274967 MFG #: AF09-30-01-13
$38.84 / EA
Usually Ships within 5-8 Days
  • Coil Power Rating: 7-1/2
  • Coil Voltage: 100 VAC, 250 VDC
  • Contact Configuration: 3NO
  • Dimensions: 86 mm H x 45 mm W x 77 mm D
  • Enclosure Type: IP20
  • Frequency Rating: 50/60
  • Maximum Load Current: 25
  • Number of Auxiliary Contacts: 1NC
  • Number of Poles: 3
  • Operating Temperature: -40 to 70
  • Series: AF09
  • Size: SZ 09
  • Terminal Type: Screw
  • Wattage: 5.5
  • Contact type: Non-Reversing
  • Mounting type: Front/Side

ABB AF09-30-01-13 IEC Contactor

ABB IEC Contactor, Series: AF09, 100 VAC, 250 VDC Coil, 25 A Maximum Load Current, 7-1/2 hp Coil, 3 Pole, 50/60 Hz Frequency, 5.5 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1NC Auxiliary Contacts, SZ 09 Size, Screw Terminal, IP20 Enclosure, -40 to 70 deg C Operating, DIN Rail Mounting, 86 mm H x 45 mm W x 77 mm D Dimensions

Additional Description: ABB -AF09-30-01-13 AF09 3P CONTR, 1NC, 100-250VAC/D

Catalog Description: AF09 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC o

  • Specifications
  • AF contactors can manage large control voltage variations one coil can be used for different control voltages used worldwide without any coil change
  • AF series contactor coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 24 to 500 VAC
  • Main poles and auxiliary contact blocks 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1
  • 6 kV rated impulse withstand voltage
  • 600/690 VAC rated insulation voltage
  • 3000 m maximum operating altitude permissible
  • 0.75 hp at 120 VAC, 1.5 hp at 240 VAC 1-phase 2 hp at 200/208 VAC, 2 hp at 220/240 VAC, 5 hp at 440/480 VAC, 7.5 hp at 550/600 VAC 3-phase power rating