ABB AF16-30-10-14 IEC Contactor
- Coil Power Rating: 15
- Coil Voltage: 250 VAC, 500 VDC
- Contact Configuration: 3NO
- Dimensions: 86 mm H x 45 mm W x 77 mm D
- Enclosure Type: IP20
- Frequency Rating: 50/60
- Maximum Load Current: 30
- Number of Auxiliary Contacts: 1
- Number of Poles: 3
- Operating Temperature: -60 to 80
- Series: AF16
- Size: 16 Frame
- Terminal Type: Screw
- Wattage: 9
- Contact type: Non-Reversing
- Mounting type: Front/Side
ABB AF16-30-10-14 IEC Contactor
ABB IEC Contactor, Series: AF16, 250 VAC, 500 VDC Coil, 30 A Maximum Load Current, 15 hp Coil, 3 Pole, 50/60 Hz Frequency, 9 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1 Auxiliary Contacts, 16 Frame Size, Screw Terminal, IP20 Enclosure, -60 to 80 deg C Operating, DIN Rail Mounting, 86 mm H x 45 mm W x 77 mm D Dimensions
Additional Description: ABB -AF16-30-10-14 CTR,3P,17A,250-500VAC/DC,1NO
Catalog Description: AF16 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC o
- Specifications
- AF contactors can manage large control voltage variations one coil can be used for different control voltages used worldwide without any coil change
- AF series contactor coils are designed to utilize both AC (50/60 Hz) and DC control circuit inputs ranging from 24 to 500 VAC
- Main poles and auxiliary contact blocks 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically linked auxiliary contacts compliant with Annex L of IEC 60947-5-1
- 6 kV rated impulse withstand voltage
- 600/690 VAC rated insulation voltage
- 3000 m maximum operating altitude permissible
- 1-1/2 hp at 120 VAC/3 hp at 240 VAC 1-phase 5 hp at 200/208 VAC/5 hp at 220/240 VAC/10 hp at 440/480 VAC/15 hp at 550/600 VAC 3-phase power rating