ABB AF80-22-00-11 Line Contactor

2305556 MFG #: AF80-22-00-11
$1,062.13 / EA
Usually Ships within 5-8 Days
  • Coil Power Rating: 30 hp, 60 hp, 75 hp, 7-1/2 hp, 25 hp, 15 hp
  • Coil Voltage: 24 to 60 VAC, 20 to 60 VDC
  • Contact Configuration: 2NO-2NC
  • Contact Rating: 125 A at 690 V
  • Dimensions: 90 mm W x 116 mm D x 125.5 mm H
  • Enclosure Type: IP10/IP20
  • Frequency Rating: 50/60
  • Maximum Load Current: 105
  • Number of Poles: 4
  • Operating Cycles: 10000000
  • Operating Temperature: -40 to 70
  • Series: AF Series
  • Size: AF80
  • Terminal Type: Screw
  • Type: Non-Reversing
  • Wattage: 22/37/45

ABB AF80-22-00-11 Line Contactor

ABB Line Contactor, Non-Reversing, Series: AF Series, 24 to 60 VAC, 20 to 60 VDC Coil, 105 A Maximum Load Current, 30 hp, 60 hp, 75 hp, 7-1/2 hp, 25 hp, 15 hp Coil, 4 Pole, 50/60 Hz Frequency, 22/37/45 kW Wattage, 2NO-2NC Contact Configuration, 125 A at 690 V Contact, AF80 Size, Screw Terminal, IP10/IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 90 mm W x 116 mm D x 125.5 mm H Dimensions

Additional Description: ABB -AF80-22-00-11 CONTACTOR 2NO-2NC POLE 105A 600VAC 4-POLE 2NO-2NC POLE 105A 600VAC

Catalog Description: AF80 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or D

  • Specifications
  • No auxiliary contacts
  • 30 hp at 220 to 240 VAC 3 ph, 60 hp at 440 to 480 VAC 3 ph, 75 hp at 550 to 600 VAC 3 ph, 7-1/2 hp at 120 VAC 1 ph, 25 hp at 200 to 208 VAC 3 ph, 15 hp at 240 VAC 1 ph
  • 22 kW at 220/230/240 V, 37 kW at 380/400 V, 45 kW at 415 V, 45 kW at 440 V, 45 kW at 500 V, 45 kW at 690 V
  • Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
  • Can manage large control voltage variations
  • Reduced panel energy consumption
  • Very distinct closing and opening
  • Built-in surge suppression
  • Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
  • 125 A at 690 V, 105 A at 690 V, 90 A at 690 V rated operational current AC-1
  • 80 A at 220/230/240 V, 80 A at 380/400 V, 80 A at 415 V, 80 A at 440 V, 65 A at 500 V, 49 A at 690 V rated operational current AC-3