WAGO 750-514 Programmable Logic Controller Distributed On Machine I/O Subsystem

356115 MFG #: 750-514
$86.90 / EA
Usually Ships within 5-8 Days
  • Actuator connection: 2 x (1-wire)
  • Color: Light gray
  • Conformity marking: CE
  • Connection technology: 8 x CAGE CLAMP®
  • Connection type (1): Inputs/outputs
  • Contact material: Ag alloy (with gold flash)
  • Country of origin: DE
  • Current carrying capacity (power jumper contacts): 0.416666666666667
  • Customs tariff number: 85371098990
  • Depth: 69.8 mm / 2.748 inch
  • Depth from upper edge of DIN-rail: 62.6 mm / 2.465 inch
  • Drop-out time (max.): 4 ms
  • Electrical switching operations (min.) (at max. resistive load): 1 x 105
  • EMC emission of interference: Per EN 61000-6-4, marine applications
  • EMC immunity to interference: Per EN 61000-6-2, marine applications
  • Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Fire load: 1.184 MJ
  • GTIN: 4045454393489
  • Height: 100 mm / 3.937 inch
  • Housing material: Polycarbonate, polyamide 6.6
  • Indicators: LED (A, C) green: Status relay 1, relay 2
  • Isolation: 1500 V (system/field)
  • Mechanical switching operations (min.) (at max. resistive load): 100 x 106
  • Mounting position: Horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail
  • Number of digital outputs: 2
  • Number of incoming power jumper contacts: 1
  • Number of outgoing power jumper contacts: 1
  • Operating altitude: 0 … 2000 m
  • Output (internal) data width (max.): 2 bit
  • Output characteristic: Potential-free
  • Output circuit design: 2 changeover contacts || Relays
  • Packaging type: BOX
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10 ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25 ppm
  • Pollution degree (5): 2 per IEC 61131-2
  • Power consumption (5 V system supply): 70 mA
  • Protection type: IP20
  • Pull-in time (max.): 4 ms
  • Relative humidity (without condensation): 0.95
  • Shock resistance: 15g per IEC 60068-2-27
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inch
  • Supply voltage (field): ; Transmission of ground potential via power jumper contact
  • Supply voltage (system): DC 5 V; via data contacts
  • Surrounding air temperature (operation): 0 … 55 °C
  • Surrounding air temperature (storage): -40 … 85 °C
  • Switching current (max.): 0.5 A
  • Switching current (min.): 0.01 mA
  • Switching current (note): 0.5 A at 125 VAC; 1 A at 30 VDC
  • Switching frequency (max.): 0.33 Hz
  • Switching power: 62.5 VA / 30 W
  • Switching voltage (max.): 125 VAC, 30 VDC V
  • Switching voltage (min.): 0.01 V
  • Total number of channels (module): 2
  • Vibration resistance: 4g per IEC 60068-2-6
  • Weight: 48.465 g
  • Width: 12 mm / 0.472 inch

2-channel relay output; 125 VAC; 0.5 A; Potential-free; 2 changeover contacts; light gray