WAGO 750-538 Programmable Logic Controller Distributed On Machine I/O Subsystem

2276569 MFG #: 750-538
$436.04 / EA
Usually Ships within 5-8 Days
  • Actuator connection: 2 x (2-wire)
  • Color: Blue
  • Conformity marking: CE
  • Connection technology: 8 x CAGE CLAMP®
  • Connection type (1): Inputs/outputs
  • Contact material: Ag alloy (with gold flash)
  • Country of origin: DE
  • Current carrying capacity (power jumper contacts): 0.0416666666666667
  • Customs tariff number: 85371098990
  • Depth: 67.8 mm / 2.669 inch
  • Depth from upper edge of DIN-rail: 60.6 mm / 2.386 inch
  • Drop-out time (max.): 4 ms
  • Electrical switching operations (min.) (at max. resistive load): 1 x 105
  • EMC emission of interference: Per EN 61000-6-3, marine applications
  • EMC immunity to interference: Per EN 61000-6-2, marine applications
  • Ex guideline: EN IEC 60079-0, -7, -11
  • Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Fire load: 0.000 MJ
  • GTIN: 4050821694823
  • Height: 100 mm / 3.937 inch
  • Housing material: Polycarbonate, polyamide 6.6
  • Intrinsic safety Ex i: Yes
  • Isolation: 300 VAC system/field
  • Load type: Resistive, inductive, lamp load
  • Marking: ATEX, IECEx, Underwriters Laboratories Inc.
  • Mechanical switching operations (min.) (at max. resistive load): 100 x 106
  • Mounting position: Horizontal (standing/lying); vertical
  • Mounting type: DIN-35 rail
  • Number of digital outputs: 2
  • Number of incoming power jumper contacts: 2
  • Number of outgoing power jumper contacts: 2
  • Operating altitude: 0 … 2000 m
  • Output (internal) data width (max.): 2 bit
  • Output characteristic: Potential-free
  • Output circuit design: 2 changeover contacts || Relays
  • Packaging type: BOX
  • Permissible H2S contaminant concentration at a relative humidity 75 %: 10 ppm
  • Permissible SO2 contaminant concentration at a relative humidity 75 %: 25 ppm
  • Pollution degree (5): 2 per IEC 61131-2
  • Power consumption (5 V system supply): 26 mA
  • Power consumption Pmax.: 0.8 W
  • Power loss Pl: 0.8 W
  • Protection type: IP20
  • Pull-in time (max.): 4 ms
  • Relative humidity (without condensation): 0.95
  • Safety-relevant data (circuit): Relay output: Ui = 30 VDC; Ii = 1 A; Pi = 30 W; Ui = 100 VAC; Ii = 0.5 A; Pi = 50 VA; Li = negligibly small; Ci = negligibly small
  • Shock resistance: 15g per IEC 60068-2-27
  • Signal type: Voltage
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 14 AWG
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inch
  • Supply voltage (field): DC 24 V; (Ex i power supply: UO = max. 27.3 V); via power jumper contacts (power supply via blade contact; transmission via spring contact)
  • Supply voltage (system): DC 5 V; via data contacts
  • Surrounding air temperature (operation): 0 … 55 °C
  • Surrounding air temperature (storage): -40 … 85 °C
  • Switching current (max.): 0.5 A
  • Switching current (min.): 0.01 mA
  • Switching current (note): 0.5 A at 100 VAC; 1 A at 30 VDC
  • Switching frequency (max.): 0.3 Hz
  • Switching power: 50 VA / 30 W
  • Switching voltage (max.): 100 VAC, 30 VDC V
  • Switching voltage (min.): 0.1 V
  • Total number of channels (module): 2
  • Vibration resistance: 4g per IEC 60068-2-6
  • Voltage signal type: AC 100 V
  • Weight: 49.100 g
  • Width: 12 mm / 0.472 inch

2-channel relay output; Potential-free; 2 changeover contacts; Intrinsically safe; blue