WAGO 787-692 Power Supply Unit

2164795 MFG #: 787-692
$322.11 / EA
Usually Ships within 5-8 Days
  • Climatic category: 3K3 (per EN 60721)
  • Conformity marking: CE
  • Connection technology: CAGE CLAMP®
  • Connection type (1): Input/output
  • Control deviation: ≤ 3 %
  • Country of origin: DE
  • Current limitation: 1.1 x Io nom (typ.)
  • Customs tariff number: 85044082900
  • Default setting: DC 30.5 V
  • Depth from upper edge of DIN-rail: 120 mm / 4.724 inch
  • Derating: -3 %/K (> 50 °C)
  • Discharge current: ≤ 0.6 mA
  • Efficiency (typ.): 89 %
  • Fine-stranded conductor: 0.08 … 2.5 mm² / 28 … 12 AWG
  • Fire load: 0.000 MJ
  • GTIN: 4045454448097
  • Height from upper-edge of DIN-rail: 133 mm / 5.236 inch
  • Input current Ii: ≤ 0.8 A (230 VAC); ≤ 1.4 A (115 VAC)
  • Input voltage range: AC 85 … 264 V; DC 120 … 300 V
  • Inrush current: ≤ 50 A
  • Internal fuse: T 4 A / 250 VAC
  • Isolation voltage (Pri.-GND): DC 2.2 kV
  • Isolation voltage (Pri.-Sec.): DC 4.242 kV
  • Isolation voltage (Sec.-GND): DC 0.7 kV
  • Load regulation: ≤ 2.5 %
  • Mains failure hold-up time: ≥ 50 ms (230 VAC)
  • Mounting type: DIN-35 rail
  • Nominal input voltage Ui nom: AC 100 … 240 V; DC 140 … 300 V
  • Nominal mains frequency range: 50 … 60 Hz; 0 Hz
  • Nominal output current Io nom: 3 A (30.5 VDC)
  • Nominal output voltage Uo nom: DC 30.5 V (SELV)
  • Note (conductor cross-section): 12 AWG: THHN, THWN
  • Open-circuit-proof: Yes
  • Operation status indicator: Green LED (30.5 V OK)
  • Output voltage range: DC 26 … 33 V (adjustable)
  • Overload behavior: Constant current
  • Overvoltage protection; secondary: Internal protective circuit || ≤ 48 VDC (in the event of a fault)
  • Packaging type: BOX
  • Parallel operation: No
  • Phases: 1
  • Pollution degree: 2
  • Power factor correction (PFC): Passive
  • Power loss (max.) Pl (max.): 14.2 W (264 VAC / 30.5 VDC; 3 A)
  • Power loss Pl: ≤ 9 W (230 VAC; No load)
  • Protection class: I
  • Protection type: IP20 (per EN 60529)
  • Recommended backup fusing: Circuit breaker: C10 or B16
  • Relative humidity: 30 … 85 % (no condensation permissible)
  • Required backup fusing: An external DC fuse is required for the DC input voltage.
  • Residual ripple: ≤ 300 mV (Peak-to-peak, < 10 kHz); ≤ 50 mV (Peak-to-peak; 10 kHz … 20 MHz)
  • Resistance to reverse feed: ≤ DC 40 V
  • Series operation: No
  • Short-circuit-protected: Yes
  • Solid conductor: 0.08 … 2.5 mm² / 28 … 12 AWG
  • Standards/Specifications: EN 60950-1; EN 61204-3; EN 61204-7; UL 60950; UL 508; GL
  • Strip length: 8 … 9 mm / 0.31 … 0.35 inch
  • Surrounding air temperature (operation): -10 … 70 °C
  • Surrounding air temperature (storage): -25 … 85 °C
  • Transient suppression (primary): Varistor
  • WAGO Connector: WAGO 231 Series
  • Weight: 650.000 g
  • Width: 51 mm / 2.008 inch

EPSITRON® power supply; single-phase; output voltage 30.5 DVC; 1.3 A