ABB AF16-30-10-12 Line Contactor

2233215 MFG #: AF16-30-10-12
$65.03 / EA
10 In Stock <strong>Ships Same Day</strong>
  • Coil Power Rating: 5 hp, 10 hp, 15 hp, 1-1/2 hp, 3 hp
  • Coil Voltage: 48 to 130
  • Contact Configuration: 3NO
  • Contact Rating: 30 A at 690 V
  • Dimensions: 45 mm W x 77 mm D x 86 mm H
  • Enclosure Type: IP20
  • Maximum Load Current: 30
  • Number of Auxiliary Contacts: 1NO
  • Number of Poles: 3
  • Operating Cycles: 10000000
  • Operating Temperature: -40 to 70
  • Series: AF Series
  • Size: AF16
  • Terminal Type: Screw
  • Type: Non-Reversing
  • Wattage: 4/7.5/9

ABB AF16-30-10-12 Line Contactor

ABB Line Contactor, Non-Reversing, Series: AF Series, 48 to 130 VAC/VDC Coil, 30 A Maximum Load Current, 5 hp, 10 hp, 15 hp, 1-1/2 hp, 3 hp Coil, 3 Pole, 4/7.5/9 kW Wattage, 3NO Contact Configuration, 1NO Auxiliary Contacts, 30 A at 690 V Contact, AF16 Size, Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 45 mm W x 77 mm D x 86 mm H Dimensions

Additional Description: ABB -AF16-30-10-12 AF16 3P CONTR, 1NO, 48-130VAC/DC

Catalog Description: AF16 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC o

QTY
  • Specifications
  • Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
  • 4 kW at 220/230/240 V, 7.5 kW at 380/400 V, 9 kW at 415 V, 9 kW at 440 V, 9 kW at 500 V, 9 kW at 690 V
  • Can manage large control voltage variations
  • Reduced panel energy consumption
  • Very distinct closing and opening
  • Built-in surge suppression
  • Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
  • 30 A at 690 V, 26 A at 690 V rated operational current AC-1
  • 18 A at 220/230/240 V, 18 A at 380/400 V, 18 A at 415 V, 18 A at 440 V, 15 A at 500 V, 10.5 A at 690 V rated operational current AC-3
  • 5 hp at 220 to 240 VAC 3 ph, 10 hp at 440 to 480 VAC 3 ph, 15 hp at 550 to 600 VAC 3 ph, 1-1/2 hp at 120 VAC 1 ph, 5 hp at 200 to 208 VAC 3 ph, 3 hp at 240 VAC 1 ph