ABB AF26ZB-30-00RT-21 DC Operated Low Coil Consumption IEC Contactor

Image Disclaimers Message
ABB AF26ZB-30-00RT-21 DC Operated Low Coil Consumption IEC Contactor
ABB AF26ZB-30-00RT-21 DC Operated Low Coil Consumption IEC Contactor
Part #:AF26ZB-30-00RT-21
SKU #: 2389271
Key Features
Part #:AF26ZB-30-00RT-21
SKU #: 2389271
Brand: ABB
Coil Power Rating: 11 kW, 15 hp, 20 hp
Coil Voltage: 24 to 60 VAC, 20 to 60 VDC
Contact Configuration: 3NO
Dimensions: 86 mm H x 45 mm W x 86 mm D
Enclosure Type: IP20
- Designed in accordance to the applicable parts of IEC60077and EN50155standard
- Shocks and vibration withstand conforming to IEC61373(category1, class B)
- Fire and smoke safety compliance to European standard EN 45545 (HL2, HL3 hazard levels)
- Electronic coil interface accepting a wide DC control voltage range (0.85 Ucminimum to 1.1Ucmaximum according to IEC60947-4-1) including several Uc control voltages (0.7 to 1.25Uc according to IEC60077) used for battery supply
- Built-in surge suppression
- Side by side mounting without restriction from -40 to 70 deg C
- 11 kW at 3-phase 400 V IEC, 15 hp at 440 to 480 VAC, 20 hp at 550 to 600 VAC
- 25.3 A at 200 to 208 VAC 3-phase UL/CSA
ABB AF26ZB-30-00RT-21 DC Operated Low Coil Consumption IEC Contactor
ABB IEC Contactor, DC Operated Low Coil Consumption, 24 to 60 VAC, 20 to 60 VDC Coil, 25.3 A Maximum Load Current, 11 kW, 15 hp, 20 hp Coil, 3 Pole, 50/60 Hz Frequency, 3NO Contact Configuration, Cable Clamp Connection, Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -60 to 80 deg C Operating, 86 mm H x 45 mm W x 86 mm D Dimensions
Additional Description: ABB -AF26ZB-30-00RT-21 24-60V50/60HZ 20-
Catalog Description: AF26ZB..RT 3-pole contactors comply with the latest railway rolling stock standards and allow installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. They are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. Improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C. Meet all main rollling stocks standards: IEC 60947-4-1, IEC 60947-5-1, IEC 60077-1/-2 and applicable parts of EN 50155 standards, shocks and vibration withstand conforming to IEC 61373 cat. 1, class B. Reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting Reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation. Electronic coil interface handling large DC voltage fluctuation voltage, including sever