ABB AF96-30-22-13 Line Contactor

2366375 MFG #: AF96-30-22-13
$211.34 / EA
Usually Ships within 5-8 Days
  • Coil Power Rating: 30 hp, 60 hp, 75 hp, 7-1/2 hp, 20 hp
  • Coil Voltage: 100 to 250
  • Contact Configuration: 3NO
  • Contact Rating: 130 A at 690 V
  • Dimensions: 70 mm W x 149 mm D x 125.5 mm H
  • Enclosure Type: IP10/IP20
  • Maximum Load Current: 115
  • Number of Auxiliary Contacts: 2NO-2NC
  • Number of Poles: 3
  • Operating Cycles: 10000000
  • Operating Temperature: -40 to 70
  • Series: AF Series
  • Size: AF96
  • Terminal Type: Screw
  • Type: Non-Reversing
  • Wattage: 25/45/55

ABB AF96-30-22-13 Line Contactor

ABB Line Contactor, Non-Reversing, Series: AF Series, 100 to 250 VAC/VDC Coil, 115 A Maximum Load Current, 30 hp, 60 hp, 75 hp, 7-1/2 hp, 20 hp Coil, 3 Pole, 25/45/55 kW Wattage, 3NO Contact Configuration, 2NO-2NC Auxiliary Contacts, 130 A at 690 V Contact, AF96 Size, Screw Terminal, IP10/IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 70 mm W x 149 mm D x 125.5 mm H Dimensions

Additional Description: ABB -AF96-30-22-13 CTR,3P,92A,100-250VAC/DC,2/2

Catalog Description: AF96 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 2 N.O. + 2 N.C. auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the ""Mechanically Linked"" symbol on the

  • Specifications
  • Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
  • 25 kW at 220/230/240 V, 45 kW at 380/400 V, 55 kW at 415 V, 55 kW at 440 V, 55 kW at 500 V, 55 kW at 690 V, 45 kW at 400 V
  • Can manage large control voltage variations
  • Reduced panel energy consumption
  • Very distinct closing and opening
  • Built-in surge suppression
  • Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
  • 130 A at 690 V, 105 A at 690 V, 90 A at 690 V rated operational current AC-1
  • 96 A at 220/230/240 V, 96 A at 380/400 V, 96 A at 415 V, 96 A at 440 V, 80 A at 500 V, 57 A at 690 V, 30 A at 1000 V rated operational current AC-3
  • 30 hp at 220 to 240 VAC 3 ph, 60 hp at 440 to 480 VAC 3 ph, 75 hp at 550 to 600 VAC 3 ph, 7-1/2 hp at 120 VAC 1 ph, 30 hp at 200 to 208 VAC 3 ph, 20 hp at 240 VAC 1 ph