Bussmann ECSR30 Key Features
| Brand: | Bussmann |
|---|---|
| Part Number # : | ECSR30 |
| SKU #: | 2332511 |
| Amperage Rating: | 30, 30 A |
| Body Type: | Cartridge, Cylindrical |
| Class: | RK5 |
| Indicating/Non-Indicating: | Non-Indicating |
| Interrupt Rating: | 200, 200 kAIC |
| Rejection/Non-Rejection: | Rejection |
| Response Time: | 10, 10 s at 500% |
| Series: | ECSR |
| Terminal Type: | Ferrule, Ferrule End, Ferrule End x Ferrule End |
| Type: | Current Limiting, Current Limiting Time Delay |
| Country of origin: | MX |
| Material: | Fiberglass |
| Mounting type: | Holder |
| Manufacturer Name: | Eaton |
| UNSPSC: | 39121606 |
| UPC: | 00782634508342 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$389.40 / 10Each
Typical price:$572.50 / Each
Quantity:
- Bussmann Bullet Fuse, Current Limiting Time Delay, Series: ECSR, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 30 A, 600 V, 200 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Ferrule End Terminal, Holder Mount, Cartridge Body Type, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size
ECSR30 Application
Industrial Facilities and Factories, Safety and Security Systems, AC Power Distribution System Mains, Feeders, Branch Circuits, Motor, Motor Branch Circuits, Transformers and Other Inductive Loads ApplicationsECSR30 Item Features
- Provides motor overload, ground fault and short circuit protection
- When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection
- The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
- Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
- Provides a higher degree of short circuit protection (greater current limitation) in circuits in which surge currents or temporary overloads occur
- Gives motor running back-up protection to motors without extra costs
- Helps protect motors against burnout from 1 ph on 3 ph systems
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- Superior overload and cycling capabilities
- https://www.youtube.com/watch?v=YMvqUyoETXk
ECSR30 Standards
CE Certified|CSA C22.2 File No.248.12 Guide JDDZ|UL File No.E162363SKU #2332511Part Number #ECSR30UNSPSC39121606UPC00782634508342