Schneider Electric LC1D253BL Tesys D Iec Contactor
Image Disclaimers Message
Schneider Electric LC1D253BL Tesys D Iec Contactor
Schneider Electric LC1D253BL Tesys D Iec Contactor
Part #:LC1D253BL
SKU #: 2292191
Key Features
Part #:LC1D253BL
SKU #: 2292191
Brand: Schneider Electric
Coil Power Rating: 2.4 W, 20
Coil Voltage: 24, 690 VAC, 24/300 VDC
Contact Configuration: 3NO
Contact Rating: 25 A at 600 VAC, 25/60 A at 600 VAC, 10/60 A at 600 VAC
Dimensions: 1.77 in W x 3.98 in D x 3.9 in H, 45 mm W x 101 mm D x 99 mm H
- 6 kV conforming to IEC 60947 rated impulse withstand voltage
- III overvoltage category
- 25 A at 140 deg F power circuit, 10 A at 140 deg F signaling circuit conventional-free air thermal current
- 450 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5 1/250 A DC signaling circuit conforming to IEC 60947-5 1 IRMS rated making capacity
- 450 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
- 40 A gG at 690 V coordination type 2 power circuit, 63 A gG at 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
- 2 MOhm at 50 Hz, Ith 25 A power circuit average impedance
- 65.45 to 88.55 ms closing and 20 to 30 ms opening operating time
- 3600 cycles/hr at 140 deg F operating rate
- Built-in bi-directional peak limiting diode suppressor coil technology
- 40 ms time constant
- 2.4 W at 68 deg F inrush power
- 2.4 W at 68 deg F hold-in power consumption
- 25 to 400 Hz signaling circuit frequency
- 5 mA minimum switching current
- 17 VAC signaling circuit minimum switching voltage
- 1.5 ms on energization between NC and NO contact/1.5 ms on de-energization between NC and NO contact non-overlap time
- >10 MOhm signaling circuit insulation-resistance
- TH protective treatment
- 3 deg of pollution, 9842.52 ft (3000 m) without derating in temperature operating altitude
- https://www.youtube.com/embed/e8UrRZljFg0
Schneider Electric LC1D253BL Tesys D Iec Contactor
Schneider Electric Square D TeSys D IEC Contactor, D-Line, Series: LC1D, 690 VAC, 24/300 VDC Coil, 25/40 A Maximum Load Current, 2.4 W Coil, 3 Pole, 50/60 Hz Frequency, 1.25/3.2 W Wattage, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 25/60 A at 600 VAC, 10/60 A at 600 VAC Contact, Spring Connection, 101/45/99 mm Size, Spring Terminal, Open Enclosure, 3600 cycles/hr Operating Cycles, -5 to 60/-40 to 70 deg C Operating, Rail/Surface Mounting, 45 mm W x 101 mm D x 99 mm H Dimensions
Additional Description: SQD -LC1D253BL (N) TeSys3PCTR25A AC3 11KW1NO1NC24VDC LC SPR NON-CANCELABLE, NON-RETURNABLE
Catalog Description: IEC contactor, TeSys Deca, nonreversing, 25A, 15HP at 480VAC, 3 phase, 3 pole, 3 NO, low consumption 24VDC coil, open style