Part Number # LP2K0901ED
SKU # 2395276
Image Disclaimers Message
LP2K0901ED
Schneider Electric LP2K0901ED, Reversing Contactor, LP2K Series, 48 VDC Coil, 9 to 20 A Maximum Load Current, 3 Pole, 50/60 Hz Frequency, 3NO Contact Configuration, 1 NC Auxiliary Contacts, 20 A Contact, Power Factor: 4 , Screw clamp Connection, 2.28 in H x 3.54 in W x 2.24 in D Size, Screw Clamp Terminal, IP20 Enclosure, 3600 cycles Operating Cycles, -13 to 122 deg F Operating, Front/Plate Rail Mounting, 2.28 in H x 3.54 in W x 2.24 in D Dimensions
Part Number # LP2K0901ED
SKU # 2395276
$210.97 /  Each
Schneider Electric LP2K0901ED Key Features
| Brand: | Schneider Electric | 
|---|---|
| Part Number # : | LP2K0901ED | 
| SKU #: | 2395276 | 
| Coil Voltage: | 48 V DC, 48 VDC | 
| Contact Configuration: | 3NO | 
| Contact Rating: | 20 A | 
| Dimensions: | 2.28 in H x 3.54 in W x 2.24 in D | 
| Enclosure Type: | IP20 | 
| Frequency Rating: | 50/60 Hz | 
| Number of Auxiliary Contacts: | 1 NC | 
| Number of Poles: | 3 | 
| Operating Cycles: | 3600 Cycles | 
| Operating Temperature: | -13 to 122 deg F | 
| Series: | LP2K Series | 
| Size: | 2.28 in H x 3.54 in W x 2.24 in D | 
| Terminal Type: | Screw Clamp | 
| Type: | Reversing Contactor | 
| Connection type: | Screw Clamp | 
| Country of origin: | FR | 
| Mounting type: | Front/Plate Rail | 
| Power factor: | 4 kW | 
| Manufacturer Name: | Schneider Electric | 
| UNSPSC: | 39121529 | 
| UPC: | 03389110498349 | 
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$210.97 /  Each
Quantity: 
- Schneider Electric LP2K0901ED, Reversing Contactor, LP2K Series, 48 V DC Coil, 9 to 20 A Maximum Load Current, 3 Pole, 50/60 Hz Frequency, 3NO Contact Configuration, 1 NC Auxiliary Contacts, 20 A Contact, Power Factor: 4 , Screw clamp Connection, 2.28 in H x 3.54 in W x 2.24 in D Size, Screw Clamp Terminal, IP20 Enclosure, 3600 cycles Operating Cycles, -13 to 122 deg F Operating, Front/Plate Rail Mounting, 2.28 in H x 3.54 in W x 2.24 in D DimensionsLP2K0901ED ApplicationFor DIN-rail and panel mounting, For connection to all control systems thanks to a 48V DC control voltage and 2NC built-in auxiliary, For motor applications, For simple motor applications rated up to 4kWLP2K0901ED IncludesA 48V DC coil, 1NC auxiliary contact, a mechanical interlock and a pre-wired reversing circuitLP2K0901ED Item Features- TeSys K contactors and overload relays are ideal for general duty applications where small size and reliability are key concerns
- A The special armature structure design allows all devices and all operating coils, either AC or DC, to have the same physical size and panel footprint for convenience
- Devices are available with low consumption DC operating coils for direct connection to PLC circuits
- Motor controlResistive load contactor application
- 8 kV uimp rated impulse withstand voltage
- III overvoltage category
- 90 A 122 deg F (50 deg C) - 1 s power circuit85 A 122 deg F (50 deg C) - 5 s power circuit80 A 122 deg F (50 deg C) - 10 s power circuit60 A 122 deg F (50 deg C) - 30 s power circuit45 A 122 deg F (50 deg C) - 1 min power circuit40 A 122 deg F (50 deg C) - 3 min power circuit80 A - 1 s signalling circuit90 A - 500 ms signalling circuit110 A - 100 ms signalling circuit20 A 122 deg F (50 deg C) - >= 15 min power circuit icw rated short-time withstand current
- 3 mOhm - Ith 20 A 50 Hz power circuit average impedance
- Power circuit 600 V UL 508Power circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-5-1Signalling circuit 600 V UL 508Power circuit 600 V CSA C22.2 No 14Signalling circuit 600 V CSA C22.2 No 14 ui rated insulation voltage
- Mechanical interlocking type
- 30 to 40 ms coil energisation and NO closing10 ms coil de-energisation and NO opening operating time
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 safety reliability level
- 5 Mcycles mechanical durability
- 02 in (0.5 mm) non overlap distance
- TC conforming to IEC 60068TC conforming to DIN 50016 protective treatment
- 2000 m without derating operating altitude
- V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102 flame retardance
- Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations contactor closed: 4 Gn, 5 to 300 Hz conforming to IEC 60068-2-6Vibrations contactor opened: 2 Gn, 5 to 300 Hz conforming to IEC 60068-2-6Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27 mechanical robustness
- With toxic heavy metal free
 LP2K0901ED StandardsUL|CSA|NF C 63-110|VDE 0660BS 5424|IEC 60947|PROP65: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.govLP2K0901ED Warranty18 monthsSKU #2395276Part Number #LP2K0901EDUNSPSC39121529UPC03389110498349