Brand: Legrand-Pass & Seymour
Legrand-Pass & Seymour 1597-I
Image Disclaimers Message
Brand: Legrand-Pass & Seymour
Legrand-Pass & Seymour 1597-I
Brand: Legrand-Pass & Seymour
Legrand-Pass & Seymour 1597-I
Part #:1597-I
SKU #: 2304594
$22.30/EA
Key Features
Part #:1597-I
SKU #: 2304594
Brand: Legrand-Pass & Seymour
Amperage Rating: 15
Dimensions: 4.2 in H x 1.73 in W x 1.03 in D
Frequency Rating: 60
NEMA Rating: NEMA 5-15R
Number of Poles: 2
$22.30/EA
- Part of the Radiant® collection
- Side or internal screw pressure plate back wire with 14 to 10 AWG solid or stranded copper wire
- Ground screw has back wire clamp for easy installation
- 10 kA short circuit current rating
- Mounting screws are shipped captive in the device and wallplate for easier installation
- High impact resistant thermoplastic construction
- Extra long strap, button colors match the device face
- Dual direction test and reset buttons
- Class A rated GFCI
- 5 +/- 1 m trip threshold, 0.025 sec trip time, 20 A feed-thru capacity, 4 to 6 mA trip level, withstands 1500 VAC minimum dielectric voltage, terminals identified in accordance with UL498 (hot, white, green)
- 95% maximum humidity, nylon face and body, 0.03 in brass contacts, galvanized steel mounting straps, thermoplastic tamper resistant shutter
- Conducts an automatic test every three sec, ensuring it's always ready to protect, if the device fails the test, the indicator light flashes to signal that the GFCI should be replaced
- Nickel plated steel 8 to 32 terminal screw
- It also has our proven SafeLock™ protection feature, if critical components are damaged and protection is lost, power to the receptacle is disconnected
- Thinner than competitor's GFCI receptacle, leaves more room for wires in the box
- Auto-ground clip assures a positive ground to metal box
- Feed through wiring configuration allows GFCI to protect downstream receptacles
- Prevents line load reversal miswire, no power to the face or downstream receptacles if wired incorrectly
- Exceeds UL 943 voltage surge requirements, survives 100x the required UL 3-gang kA/6 kV voltage surge test cycles
- Trip indicator light (red LED), two backwire holes per terminal
Specifications
Brand: Legrand-Pass & Seymour
Amperage Rating: 15
Dimensions: 4.2 in H x 1.73 in W x 1.03 in D
Frequency Rating: 60
NEMA Rating: NEMA 5-15R
Number of Poles: 2
Number of Wires: 3
Series: 1597
Temperature Rating (Degrees F): -35 to 66
Terminal Type: Screw
Type: Self-Test
Voltage Rating: 125
Color: Ivory
Material: Nylon
UNSPSC: 39121633
UPC: 00785007035735
Legrand-Pass & Seymour 1597-I
Additional Description: PS -1597I RADIANT SLF TST DUP GFCI 15A, 125V IV IV IV
Item Features