Legrand-Pass & Seymour 1597-I Key Features
| Brand: | Legrand-Pass & Seymour |
|---|---|
| Part Number # : | 1597-I |
| SKU #: | 2304594 |
| Amperage Rating: | 15, 15 A |
| Dimensions: | 1.03 in L x 1.73 in W x 4.2 in H, 4.2 in H x 1.73 in W x 1.03 in D |
| Frequency Rating: | 60, 60 Hz |
| NEMA Rating: | NEMA 5-15R |
| Number of Poles: | 2 |
| Number of Wires: | 3 |
| Series: | 1597 |
| Temperature Rating (Degrees F): | -35 to 66, -35 to 66 deg C |
| Terminal Type: | Back/Side Wire/Screw, Screw |
| Type: | Duplex Self-Test, Self-Test |
| Color: | Ivory |
| Country of origin: | CN |
| Material: | Nylon, Nylon/Thermoplastic |
| Manufacturer Name: | Legrand |
| UNSPSC: | 39121406 |
| UPC: | 00785007035735 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Legrand-Pass & Seymour 1597-I
Brand: Legrand-Pass & Seymour
Part Number: 1597-I
Additional Description: PS -1597I RADIANT SLF TST DUP GFCI 15A, 125V IV IV IV
Catalog Description: GFCI receptacles from the radiant Registered Collection self-test automatically every three seconds to ensure reliable protection from shock due to ground fault occurrences. Meeting National Electrical Code requirements for ground fault protection, GFCI receptacles make it easier to recognize and fix trips right where they happen – no more confusion at the breaker box. Maximize safety, in style, with GFCI protection featuring the sleek, clean lines of radiant. GFCI protection is required by code in bathrooms, kitchens, garages, basements, outdoor areas, and for any other outlets found within six feet of a sink or water source. GFCI outlets should always be used when replacing existing GFCI outlets during renovation. Made exclusively for use with screwless Wall Plates from the radiant Registered Collection, sold separately. Spec-Grade devices are engineered to meet federal specifications for use in commercial installations.
1597-I Specifications
- Part of the Radiant® collection
- Side or internal screw pressure plate back wire with 14 to 10 AWG solid or stranded copper wire
- Ground screw has back wire clamp for easy installation
- 10 kA short circuit current rating
- Mounting screws are shipped captive in the device and wallplate for easier installation
- High impact resistant thermoplastic construction
- Extra long strap, button colors match the device face
- Dual direction test and reset buttons
- Class A rated GFCI
- 5 +/- 1 m trip threshold, 0.025 sec trip time, 20 A feed-thru capacity, 4 to 6 mA trip level, withstands 1500 VAC minimum dielectric voltage, terminals identified in accordance with UL498 (hot, white, green)
- 95% maximum humidity, nylon face and body, 0.03 in brass contacts, galvanized steel mounting straps, thermoplastic tamper resistant shutter
- Conducts an automatic test every three sec, ensuring it's always ready to protect, if the device fails the test, the indicator light flashes to signal that the GFCI should be replaced
- Nickel plated steel 8 to 32 terminal screw
- It also has our proven SafeLock™ protection feature, if critical components are damaged and protection is lost, power to the receptacle is disconnected
- Thinner than competitor's GFCI receptacle, leaves more room for wires in the box
- Auto-ground clip assures a positive ground to metal box
- Feed through wiring configuration allows GFCI to protect downstream receptacles
- Prevents line load reversal miswire, no power to the face or downstream receptacles if wired incorrectly
- Exceeds UL 943 voltage surge requirements, survives 100x the required UL 3-gang kA/6 kV voltage surge test cycles
- Trip indicator light (red LED), two backwire holes per terminal
1597-I Application
Industrial, Health Care, Education, Institutional, Retail, Office, Hospitality/Lodging and Multiple Dwelling, Commercial and Residential Applications1597-I Item Features
- Protects against shock caused by ground-fault occurrences
- Unlike breaker alternatives, GFCI receptacles make it easier to fix trips with a reset button right on the device
- Conducts an industry-leading automatic self-test every 3 seconds
- If the device ever fails, the indicator light flashes to signal it should be replaced
- Equipped with proven SafeLock protection feature - if critical components are damaged and protection is lost, power to the outlet is disconnected
- Extends GFCI protection to downstream outlets when used with feed-thru wiring configuration
- Note, Will cut power to face and downstream outlets if wired incorrectly
- Replaces any standard receptacle with ease, in as little as 10 min
- Features durable, high-impact resistant thermoplastic construction
- More color options available to fit any style, including finishes to match current hardware and lighting trends
- Complete the look with a sleek, screwless radiant Wall Plate, and coordinate with other designer switches and outlets available from the radiant Collection
1597-I Standards
FULs Listed|UL 498|UL 94 V-2 Flammability Rated|UL ListedSKU #2304594Part Number #1597-IUNSPSC39121406UPC00785007035735