Part Number # SGF15V
SKU # 2305153
Image Disclaimers Message
Arrowhart SGF15V Key Features
| Brand: | Arrowhart | 
|---|---|
| Part Number # : | SGF15V | 
| SKU #: | 2305153 | 
| Amperage Rating: | 15, 15 A | 
| Dimensions: | 4.2 in H x 1.68 in W x 1.27 in D, 4.2 in L x 1.68 in W x 1.27 in D | 
| Enclosure: | IP65 | 
| Frequency Rating: | 60, 60 Hz | 
| NEMA Rating: | NEMA 5-15R | 
| Number of Poles: | 2 | 
| Number of Wires: | 3 | 
| Series: | SGF | 
| Temperature Rating (Degrees F): | -31 to 150.8, -35 to 66, -35 to 66 deg C | 
| Terminal Type: | Back/Side Wire, Back/Side Wired, Back/Side Wired Screw | 
| Type: | Duplex, Duplex Grounding Self-Test | 
| Color: | Ivory | 
| Material: | Polypropylene/PVC/Thermoplastic, Thermoplastic | 
| Manufacturer Name: | Eaton | 
| UNSPSC: | 39121633 | 
| UPC: | 00032664742378 | 
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
- Eaton Wiring Devices GFCI Receptacle, Duplex, Series: SGF, 125 V AC, 15 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-15R NEMA Rating, IP65 Enclosure, -35 to 66 deg C, Back/Side Wire Terminal, Thermoplastic, Ivory, 4.2 in L x 1.68 in W x 1.27 in D DimensionsSGF15V ApplicationCommercial, Industrial and InstitutionalSGF15V IncludesMatching Thermoplastic WallplateSGF15V Item Features- If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
- Performs periodic self-tests to ensure integrity of GFCI protection
- Visual trip indicator light gives quick notification of a tripped or end of life condition
- Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
- Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
- Tamper resistant shutters help prevent foreign objects from being inserted
- Line side terminals are backed out and staked for fast installation
- Horizontal test/reset button alignment provides larger unobstructed area
- Test and reset buttons are color matched to provide superior aesthetics
- Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
- Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
- Tri-combo head terminal and mounting screws
- Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
- Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts material
- #8-32 steel, brass plated, neutral screw nickel plated, ground screw green terminal and ground screws, 0.07 in thick steel terminal clamps
- Withstands 2000 V per UL498 dielectric voltage
- V2 rated UL94 flammability
- Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
- #14 to 10 AWG terminal accommodation, Back Wire and Side Wire
- https://www.youtube.com/watch?v=jwMf03OS_TE&t=5s
 SGF15V StandardscULus Listed to UL 498|UL 943|E60120|UL 508|CSA Certified|NOM CertifiedSKU #2305153Part Number #SGF15VUNSPSC39121633UPC00032664742378