Part Number # XT2SU3070AFF000XXX
SKU # 2453545
Image Disclaimers Message
XT2SU3070AFF000XXX
ABB XT2SU3070AFF000XXX Tmax XT Low Voltage Molded Case Circuit Breaker, 600/690 VAC, 70 A, 22 kA Interrupt, 3 Poles, Electronic Trip
Part Number # XT2SU3070AFF000XXX
SKU # 2453545
$750.55
Typical price:$2469.87 / 
XT2SU3070AFF000XXX Key Features
| Part Number # : | XT2SU3070AFF000XXX | 
|---|---|
| SKU #: | 2453545 | 
| Amperage Rating: | 70 A | 
| Dimensions: | 5.12 in H x 3.54 in W x 3.25 in D | 
| Frame: | XT2 125A | 
| Frequency Rating: | 50/60 Hz | 
| Interrupt Rating: | 22 kA | 
| Number of Poles: | 3 | 
| Series: | Tmax XT | 
| Temperature Rating (Degrees F): | -13 to 158 deg F | 
| Trip Range: | 70 to 700 A | 
| Trip Type: | Electronic | 
| Type: | Low Voltage | 
| Connection type: | Front Line/Load Side | 
| Country of origin: | IT | 
| Manufacturer Name: | ABB | 
| UNSPSC: | 39121616 | 
| UPC: | 888614403451 | 
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$750.55
Typical price:$2469.87 / 
Quantity: 
- ABB, XT2SU3070AFF000XXX, Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 70 A, 50/60 Hz Frequency, 22 kA Interrupt, XT2 125A Frame, Electronic Trip, 70 to 700 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D DimensionsXT2SU3070AFF000XXX ApplicationFor all distribution levels from the main low voltage switchboard to the sub-switchboards in the installationXT2SU3070AFF000XXX Item Features- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- F front terminals, no lugs installed on line and load side termination (top/bottom)
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- 22 kA standard breaking capacity
- Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
 XT2SU3070AFF000XXX StandardsRoHs, CSA, cUL, CE, GOSTSKU #2453545Part Number #XT2SU3070AFF000XXXUNSPSC39121616UPC888614403451