Part Number # LC2D80G7
SKU # 643932
Image Disclaimers Message
Square D LC2D80G7 Key Features
Brand: | Square D |
---|---|
Part Number # : | LC2D80G7 |
SKU #: | 643932 |
Coil Power Rating: | 26, 60, 60 hp |
Coil Voltage: | 120, 120 VAC, 120/1000 VAC, 300 VDC |
Contact Configuration: | 3NO |
Contact Rating: | 80 A at 575 VAC |
Dimensions: | 182 mm W x 158 mm D x 127 mm H, 5 in H x 7.17 in W x 6.22 in D, 7.17 in W x 6.22 in D x 5 in H |
Enclosure Type: | IP20 |
Frequency Rating: | 50/60, 50/60 Hz, 60 |
Number of Auxiliary Contacts: | 1NO-1NC |
Number of Poles: | 3 |
Operating Cycles: | 3600, 4000000, 4000000 Cycles |
Operating Temperature: | -4 to 140, -4 to 140 deg F, -5 to 60/-40 to 70 |
Series: | LC1D, LC2D |
Size: | 127/158/182 |
Terminal Type: | Screw Clamp |
Type: | D-Line Mechanical, LC1D D-Line, Reversing |
Wattage: | 12.5/5.1, 12.5/5.1 W |
Connection type: | Screw Clamp |
Mounting type: | Plate/Rail, Rail/Surface, Surface |
UNSPSC: | 39121529 |
UPC: | 00785901457190 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$1202.23 / Each
Quantity:
Square D LC2D80G7
Brand: Square D
Part Number: LC2D80G7
Additional Description: SQD -LC2D80G7 REVERSING CONTACTOR IEC +OPTIONS
Catalog Description: TeSys Deca reversing contactor - 3P(3 NO) - AC-3/AC-3e - <= 440 V 80 A - 120 V AC coil
LC2D80G7 Item Features
- Preassembled with reversing power busbar
- 6 kV conforming to IEC 60947 rated impulse withstand voltage
- III overvoltage category
- 125 A at <=140 deg F (60 deg C) power circuit/10 A at <=140 deg F (60 deg C) signaling circuit conventional free air thermal current
- 1100 A at 440 V power circuit conforming to IEC 60947/140 A AC signaling circuit conforming to IEC 60947-5-1/250 A DC signaling circuit conforming to IEC 60947-5-1 irms rated making capacity
- 1100 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
- 160 A gG at <=690 V coordination type 2 power circuit/200 A gG at <=690 V coordination type 1 power circuit/10 A gG signaling circuit conforming to IEC 60947-5-1 associated fuse rating
- At 50 Hz - Ith 60 A for power circuit average impedance
- Mechanical interlock
- 6 to 20 ms opening/20 to 35 ms closing operating time
- 3600 cycles/hr at <=140 deg F (60 deg C) operating rate
- Without built-in suppressor module coil technology
- 245 VA at 68 deg F (20 deg C) 50/60 Hz inrush power
- 26 VA at 68 deg F (20 deg C) 60 Hz/26 VA at 68 deg F (20 deg C) 50 Hz hold-in power consumption
- 6 to 10 W heat dissipation
- 25 to 400 Hz signaling circuit frequency
- 5 mA signaling circuit minimum switching current
- 17 V signaling circuit minimum switching voltage, TH protective treatment
- 1.5 ms on de-energisation (between NC and NO contacts)/1.5 ms on energisation (between NC and NO contacts) non-overlap time, >10 MOhm signaling circuit insulation resistance
- -40 to 158 deg F permissible ambient air temperature around the device, -76 to 176 deg F storage temperature
SKU #643932Part Number #LC2D80G7UNSPSC39121529UPC00785901457190