ABB AF38-40-00-13 Key Features
ABB AF38-40-00-13 Line Contactor
Brand: ABB
Part Number: AF38-40-00-13
ABB Line Contactor, Non-Reversing, Series: AF Series, 100 to 250 VAC/VDC Coil, 55 A Maximum Load Current, 10 hp, 25 hp, 30 hp, 2 hp, 5 hp Coil, 4 Pole, 5.5/11/9 kW Wattage, 4NO Contact Configuration, 55 A at 690 V Contact, AF38 Size, Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 45 mm W x 101 mm D x 86 mm H Dimensions
Additional Description: ABB -AF38-40-00-13 AF38 4P CONTR, 100-250VAC/DC
Catalog Description: AF38 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 4 N.O. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operate
AF38-40-00-13 Application
For controlling single and 3 ph motors and switching power circuitsAF38-40-00-13 Item Features
- No auxiliary contacts
- Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
- Can manage large control voltage variations
- Reduced panel energy consumption
- Very distinct closing and opening
- Built-in surge suppression
- Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
- 55 A at 690 V, 45 A at 690 V, 37 A at 690 V rated operational current AC-1
- 23.2 A at 220/230/240 V, 22 A at 380/400 V, 21.2 A at 415 V, 20 A at 440 V, 17.6 A at 500 V, 10.5 A at 690 V rated operational current AC-3
- 10 hp at 220 to 240 VAC 3 ph, 25 hp at 440 to 480 VAC 3 ph, 30 hp at 550 to 600 VAC 3 ph, 2 hp at 120 VAC 1 ph, 10 hp at 200 to 208 VAC 3 ph, 5 hp at 240 VAC 1 ph
- 5.5 kW at 220/230/240 V, 11 kW at 415 V, 11 kW at 440 V, 11 kW at 500 V, 9 kW at 690 V, 11 kW at 400 V
AF38-40-00-13 Standards
BAA Compliant|BV Certified|CB Certified|CCC Certified|CE Certified|cUL Listed|DNV Certified|EAC Certified|GL Certified|LR Certified|RMRS Certified|RINA Certified|RoHS CompliantSKU #2280280Part Number #AF38-40-00-13UNSPSC39121529UPC03471523115330