ABB AF38Z-40-00-23 Line Contactor

2280281 MFG #: AF38Z-40-00-23
$124.18 / EA
Usually Ships within 5-8 Days
  • Coil Power Rating: 10 hp, 25 hp, 30 hp, 2 hp, 5 hp
  • Coil Voltage: 100 to 250
  • Contact Configuration: 4NO
  • Contact Rating: 55 A at 690 V
  • Dimensions: 45 mm W x 101 mm D x 86 mm H
  • Enclosure Type: IP20
  • Maximum Load Current: 55
  • Number of Poles: 4
  • Operating Cycles: 10000000
  • Operating Temperature: -40 to 70
  • Series: AFZ
  • Size: AF38
  • Terminal Type: Screw
  • Type: Non-Reversing
  • Wattage: 5.5/11/9

ABB AF38Z-40-00-23 Line Contactor

ABB Line Contactor, Non-Reversing, Series: AFZ, 100 to 250 VAC/VDC Coil, 55 A Maximum Load Current, 10 hp, 25 hp, 30 hp, 2 hp, 5 hp Coil, 4 Pole, 5.5/11/9 kW Wattage, 4NO Contact Configuration, 55 A at 690 V Contact, AF38 Size, Screw Terminal, IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 45 mm W x 101 mm D x 86 mm H Dimensions

Additional Description: ABB -AF38Z-40-00-23 AF38Z 4P CONTR, 100-250VAC/DC NON-CANCELABLE, NON-RETURNABLE

Catalog Description: AF38Z 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output ? 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 4 N.O. main

  • Specifications
  • Compact, space saving design
  • 23.2 A at 220/230/240 V, 22 A at 380/400 V, 21.2 A at 415 V, 20 A at 440 V, 17.6 A at 500 V, 10.5 A at 690 V rated operational current AC-3
  • 10 hp at 220 to 240 VAC 3 ph, 25 hp at 440 to 480 VAC 3 ph, 30 hp at 550 to 600 VAC 3 ph, 2 hp at 120 VAC 1 ph, 10 hp at 200 to 208 VAC 3 ph, 5 hp at 240 VAC 1 ph
  • 5.5 kW at 220/230/240 V, 11 kW at 415 V, 11 kW at 440 V, 11 kW at 500 V, 9 kW at 690 V, 11 kW at 400 V
  • No auxiliary contacts
  • Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
  • Can manage large control voltage variations
  • Reduced panel energy consumption
  • Very distinct closing and opening
  • Built-in surge suppression
  • Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
  • 55 A at 690 V, 45 A at 690 V, 37 A at 690 V rated operational current AC-1