ABB AF65-30-11-14 Line Contactor
Image Disclaimers Message
ABB AF65-30-11-14 Line Contactor
ABB AF65-30-11-14 Line Contactor
Part #:AF65-30-11-14
SKU #: 2277546
Key Features
Part #:AF65-30-11-14
SKU #: 2277546
Brand: ABB
Coil Power Rating: 25 hp, 50 hp, 60 hp, 5 hp, 20 hp, 15 hp
Coil Voltage: 250 to 500, 250 to 500 VAC/VDC
Contact Configuration: 3NO
Contact Rating: 105 A at 690 V
Dimensions: 67 mm W x 111 mm D x 125.5 mm H
- Control circuit - AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100 to 250 VAC and VDC), only 4 control voltage ranges covering 24 to 500 V 50/60 Hz and 20 to 500 VDC
- Can manage large control voltage variations
- Reduced panel energy consumption
- Very distinct closing and opening
- Built-in surge suppression
- Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories
- 105 A at 690 V, 90 A at 690 V, 80 A at 690 V rated operational current AC-1
- 65 A at 220/230/240 V, 65 A at 380/400 V, 65 A at 415 V, 65 A at 440 V, 55 A at 500 V, 39 A at 690 V rated operational current AC-3
- 25 hp at 220 to 240 VAC 3 ph, 50 hp at 440 to 480 VAC 3 ph, 60 hp at 550 to 600 VAC 3 ph, 5 hp at 120 VAC 1 ph, 20 hp at 200 to 208 VAC 3 ph, 15 hp at 240 VAC 1 ph
- 18.5 kW at 220/230/240 V, 30 kW at 380/400 V, 37 kW at 415 V, 37 kW at 440 V, 37 kW at 500 V, 37 kW at 690 V, 30 kW at 400 V
ABB AF65-30-11-14 Line Contactor
ABB Line Contactor, Non-Reversing, Series: AF Series, 250 to 500 VAC/VDC Coil, 90 A Maximum Load Current, 25 hp, 50 hp, 60 hp, 5 hp, 20 hp, 15 hp Coil, 3 Pole, 18.5/30/37 kW Wattage, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 105 A at 690 V Contact, AF65 Size, Screw Terminal, IP10/IP20 Enclosure, 10000000 Cycles Operating Cycles, -40 to 70 deg C Operating, 67 mm W x 111 mm D x 125.5 mm H Dimensions
Additional Description: ABB -AF65-30-11-14 CTR,3P,68A,250-500VAC/DC,1/1
Catalog Description: AF65 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with side-mounted 1 N.O. + 1 N.C. auxiliary contact block, front-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N