Image Disclaimers Message
Brand: ABB
ABB MS132-1.0 Manual Motor Starter
Part Number # MS132-1.0
SKU # 2258590
$173.51 / Each
ABB MS132-1.0 Key Features
Brand: ABB
Part Number # MS132-1.0
SKU #2258590
Action: On/Off/Trip
Amperage Rating: 0.63 to 1, 0.63 to 1 A, 1
Control Type: Rotary Handle
Dimensions: 90 mm H x 45 mm W x 86.75 mm D
Enclosure Type: IP20
Frequency Rating: 50/60, 50/60 Hz
Full Load Current: 1 A
Load Capacity: 100, 100 kA
Motor Power: 1/2, 1/2 hp
Number of Poles: 3
Operating Cycles: 100000, 100000 Cycles
Operating Temperature: -25 to 70, -25 to 70 deg C
Overload Relay: Class 10 Thermal
Phase: 3
Series: MS132
Setting: 0.63 to 1, 0.63 to 1 A
Voltage Rating: 690 VAC/250 VDC
Wattage: 0.25, 0.25 kW
Connection type: Thread, Threaded
Country of origin: DE
Manufacturer Name: ABB
UNSPSC: 39121521
UPC: 04013614400056
$173.51 / Each
ABB MS132-1.0 Manual Motor Starter
Brand: ABB
Part Number: MS132-1.0
ABB Manual Motor Starter, Series: MS132, 690 VAC/250 VDC, 0.63 to 1 A, 50/60 Hz Frequency, 0.25 kW Wattage, 1/2 hp Motor, 3 Pole, Setting: 0.63 to 1 A, 100 kA Load, 3 ph, Thread Connection, ON/OFF/Trip Action, Rotary Handle Control, IP20 Enclosure, 100000 Cycles Operating Cycles, -25 to 70 deg C Operating, 90 mm H x 45 mm W x 86.75 mm D Dimensions
Additional Description: ABB -MS132-1.0 3P MMP 0.63-1.0A RANGE
Catalog Description: 3 pole, 0.63 to 1.0 amp, UL rated, MS132 manual motor protector
MS132-1.0 Application
For use as a motor disconnect in single motor applications, group motor installations, tap conductor protection and Type E and F combination motor controllersMS132-1.0 Item Features
- Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under short circuit condition, by switching off the motor within milliseconds
- 1 A at 200 VAC, 208 VAC, 220 to 240 VAC, 440 to 480 VAC, 550 to 600 VAC
- Manual motor starters are electromechanical protection devices for the main circuit
- Disconnect function
- 0.25 kW at 400 VAC rated operational power
- Clear switch position indication on/off, trip
- They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures
- Electrical 50000 cycle, mechanical 100000 cycle
- Phase loss sensitivity
- Adjustable current setting for overload protection
- Fuse less starter combinations are setup together with contactors
MS132-1.0 Standards
cULus Listed|UL 508|CSA C22.2 No. 14|CE Certified|CCC Certified|BV Approved|CB Approved|ABS Approved|DNV Approved|GL Approved|UL 508|ABS Certified|ATEX Certified|BV Certified|CB Certified|CCC Certified|cUL Listed|cULus Listed|DNV GL Certified|EAC Certified|GOST Certified|LR Certified|RINA Certified|RMRS CertifiedSKU #2258590Part Number #MS132-1.0UNSPSC39121521UPC04013614400056