ABB UA16-30-10-RA-84 Key Features
ABB UA16-30-10-RA-84
Brand: ABB
Part Number: UA16-30-10-RA-84
ABB IEC Contactor, AC Operated, 110/110 to 120 VAC Coil, 20 kV Coil, 3 Pole, 50/60 Hz Frequency, 3NO Contact Configuration, 1NO Auxiliary Contacts, Screw Terminal, IP20 Enclosure, 100000/250000 Cycles Operating Cycles, 4.72 in H x 1.73 in W x 4.21 in D Dimensions
Additional Description: ABB -UA16-30-10-RA-84 CONT,3P,20KVAR 600VAC,110-120VAC CO
Catalog Description: UA16..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals Less than or Equal to 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V Less than or Equal to Ue Less than or Equal to 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the hi
UA16-30-10-RA-84 Application
For capacitor switching can be used for installations in which the peak current far exceeds 100 times nominal rms currentUA16-30-10-RA-84 Item Features
- The contactors are delivered complete with their damping resistors and must be used without additional inductances
- The capacitors must be discharged (maximum residual voltage at terminals ? 50 V) before being re-energized when the contactors are making
- 3 main poles and 1 built-in auxiliary contact
- The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank
- Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles
- The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level
- 20 kV at 600 V UL/CSA
UA16-30-10-RA-84 Standards
UL Listed|CSA Certified|IEC 60947-1|IEC 60947-4-1|IEC EN 60947-1|IEC 60947-4-1SKU #2445155Part Number #UA16-30-10-RA-84UNSPSC39121529UPC03471522300843