EYD36
Appleton EYD36
Part Number # EYD36
SKU # 2466459
Appleton EYD36 Key Features
| Brand: | Appleton |
|---|---|
| Part Number # : | EYD36 |
| SKU #: | 2466459 |
| Dimensions: | 4.31 in L x 2.19 in W |
| Material: | Grayloy-Iron |
| UNSPSC: | 39121311 |
| UPC: | 00781381620895 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Appleton EYD36
Brand: Appleton
Part Number: EYD36
Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EYD, 1 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Grayloy-Iron, Gray, Triple Coated, 4.31 in L x 2.19 in W
Additional Description: APLE-EYD36 1 MALE DRAIN SEAL
Catalog Description: UNILETS EYD Series 25 PCT Fill Vertical Conduit Drain Sealing Fitting With Removable Nipple, Size: 1 IN, Material: Grayloy-Iron, Finish: Triple-Coat (Zinc Electroplate, Chromate And Epoxy Powder Coat), Color: Gray, Connection: Tapered MNPT X Tapered FNPT, Turning Radius: 1.38 IN, Length: 4.31 IN, Width: 2.19 IN, Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Division 1 And 2 Groups C, D, Class II, Division 1 And 2 Groups E, F, G, Class III, For Use With Threaded Rigid Metal Conduit and IMC
EYD36 Application
For prevent passage of gases, vapors or flames from one portion of conduit system to anotherEYD36 Item Features
- Smooth, rounded integral bushing in each hub to protect conductor insulation
- Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
- Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
- Restrict any explosion to the sealed off enclosure
- Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
- Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
- Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
- Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
- Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
- Tapered MNPT X tapered FNPT connection
- 25% fill vertical conduit drain sealing fittings
- Chromate/epoxy powder coated/zinc electroplated finish
EYD36 Standards
UL 886|UL 1203|UL File No. E10444|CSA C22.2 No. 30|CSA 065181|Class I, Div 1 and 2, Groups C, D|Class II, Div 1 and 2, Groups E, F, G|Class IIISKU #2466459Part Number #EYD36UNSPSC39121311UPC00781381620895
Image provided may only be a representation of final product and may include optional equipment