Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 4 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Almag 35 Aluminum, Epoxy Powder Coated, 9.38 in L x 5.13 in W
Additional Description: APLE-EYF400AL 4 ALMAG 35 SEALING FITTING
Catalog Description: Explosionproof Rigid/IMC Conduit Seal, Turning Radius 3.69 Inch, Trade Size 4 Inch, Connection Type Female, Material Epoxy Powder Coated Almag 35 Aluminum, Mounting Position Horizontal/Vertical, Enclosure Class I Div 1 and 2 Group A B C D, Class II Div 1 and 2 Group E F G, Class III, Approval UL 886/E10444, CSA C22.2, Size 9.38 Inch L x 5.13 Inch W, Constructional Feature Explosionproof, Dust-Ignitionproof, Raintight, Used On Threaded Rigid/IMC Metal Conduit
EYF400AL Application
For prevent passage of gases, vapors or flames from one portion of conduit system to anotherEYF400AL Item Features
- Smooth, rounded integral bushing in each hub to protect conductor insulation
- Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
- Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
- Restrict any explosion to the sealed off enclosure
- Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
- Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
- Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
- Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
- Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
- 25% fill vertical and horizontal conduit sealing fittings for close turning radius
EYF400AL Standards
UL 886|UL 1203 File No. E10444|CSA C22.2 No. 30|CSA 065181SKU #2469784Part Number #EYF400ALUNSPSC39121311UPC00781381600088