Part Number # GV2RT06
SKU # 2296116
Image provided may only be a representation of
final product and may include optional equipment
GV2RT06
Schneider Electric GV2RT06 Manual Starter
Part Number # GV2RT06
SKU # 2296116
Schneider Electric GV2RT06 Key Features
| Brand: | Schneider Electric |
|---|---|
| Part Number # : | GV2RT06 |
| SKU #: | 2296116 |
| Amperage Rating: | 1.6, 1.6 A |
| Control Type: | Rocker Lever |
| Dimensions: | 89 mm H x 45 mm W x 78.5 in D |
| Enclosure Type: | IP20 |
| Frequency Rating: | 50/60, 50/60 Hz |
| Motor Power: | 0.18/0.25/0.37/0.55/0.75/1.1, 0.18/0.25/0.37/0.55/0.75/1.1 kW |
| Number of Poles: | 3 |
| Operating Cycles: | 100000, 100000 Cycles |
| Operating Temperature: | -20 to 60, -20 to 60 deg C |
| Overload Relay: | Class 10 Ambient Compensated |
| Phase: | 3 |
| Reset Type: | Manual |
| Series: | TeSys GV2RT, TeSys™ GV2RT |
| Setting: | 1 to 1.6, 1 to 1.6 A |
| Type: | Circuit Breaker Thermal Magnetic |
| Connection type: | Screw Clamp |
| Country of origin: | FR |
| Manufacturer Name: | Schneider Electric |
| UNSPSC: | 39121521 |
| UPC: | 00785901408987 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Schneider Electric GV2RT06 Manual Starter
Brand: Schneider Electric
Part Number: GV2RT06
Schneider Electric Square D Manual Starter, Circuit Breaker Thermal Magnetic, Series: TeSys GV2RT, 690 VAC, 1.6 A, 50/60 Hz Frequency, 0.18/0.25/0.37/0.55/0.75/1.1 kW Motor, 3 Pole, Setting: 1 to 1.6 A, Manual Reset, 3 ph, Screw Clamp Connection, Class 10 Ambient Compensated Overload Relay, Rocker Lever Control, IP20 Enclosure, 100000 Cycles Operating Cycles, -20 to 60 deg C Operating, 89 mm H x 45 mm W x 78.5 in D Dimensions
Additional Description: SQD -GV2RT06 (N) GV2 MOTOR CB HIGH INRUSH 1-1.6A TOGGLE NON-CANCELABLE, NON-RETURNABLE
Catalog Description: TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, toggle switch, 1…1.6 A, screw clamp terminals
GV2RT06 Application
Food and Beverage, Material Working, Material Handling, Small Pumps and PackagingGV2RT06 Item Features
- Manual and local control, when the motor circuit-breaker is used on its own and automatic and remote control when combined with a contactor
- Motor protection provided by thermal magnetic devices built into the circuit breaker
- No live parts are accessible to direct finger contact
- The addition of an undervoltage trip enables the motor circuit breaker to be tripped if voltage is lost
- The addition of a shunt trip enables remote control of tripping
- The control for the open or enclosed motor circuit breaker can be locked in the "N/C" position using 3 padlocks
- The system manages motors and other electrical loads up to 40 hp
- Up to 20 modules and 1 bus coupler (up to 112 cm L)
- One click mounting on DIN rail and no need for control wiring on modules
- No auxiliary wiring required, thanks to full connectivity over fieldbus
- All adjustments and setting are digitized, no mechanical dials or dip switches
- Energy monitoring at load level
- Detect and solve issues before your machine stops
- Gain better insight to the operation and performance of the machine
- Decrease time to market, helping improve project profitability
- 0.18 kW at 220/230 VAC, 0.25 kW at 220/230 VAC, 0.37 kW at 400/415/440/500 VAC, 0.55 kW at 400/415/440/550 VAC, 0.75 kW at 500/690 VAC, 1.1 kW at 690 VAC motor rating
- https://www.youtube.com/embed/YkQwgPFibOM
GV2RT06 Standards
RoHS Compliant|IEC 60947-4-1|EN 60204|NF C 63-120|VDE 0113|CSA C22.2|IEC 60947-2|UL 508|NFC 63-650|IEC 60947-1|VDE 0660|NFC 79-130|EAC Certified|UL Listed|CCC Certified|CSA Certified|REACH Compliant|WEEE Compliant|Green Premium|ECCN: EAR99|PROP65: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.govSKU #2296116Part Number #GV2RT06UNSPSC39121521UPC00785901408987