Part Number # GV2RT07
SKU # 2303892
Image Disclaimers Message
GV2RT07
Schneider Electric GV2RT07 Manual Starter
Part Number # GV2RT07
SKU # 2303892
$154.27 /  Each
Typical price:$178.20 / Each
Schneider Electric GV2RT07 Key Features
| Brand: | Schneider Electric | 
|---|---|
| Part Number # : | GV2RT07 | 
| SKU #: | 2303892 | 
| Amperage Rating: | 2.5, 2.5 A | 
| Control Type: | Rocker Lever | 
| Dimensions: | 89 mm H x 45 mm W x 78.5 in D | 
| Enclosure Type: | IP20 | 
| Frequency Rating: | 50/60, 50/60 Hz | 
| Motor Power: | 0.37/0.75/1.1/1.5, 0.37/0.75/1.1/1.5 kW | 
| Number of Poles: | 3 | 
| Operating Cycles: | 100000, 100000 Cycles | 
| Operating Temperature: | -20 to 60, -20 to 60 deg C | 
| Overload Relay: | Class 10 Ambient Compensated | 
| Phase: | 3 | 
| Reset Type: | Manual | 
| Series: | TeSys GV2RT, TeSys™ GV2RT | 
| Setting: | 1.6 to 2.5, 1.6 to 2.5 A | 
| Type: | Circuit Breaker Thermal Magnetic | 
| Connection type: | Screw Clamp | 
| Country of origin: | FR | 
| Manufacturer Name: | Schneider Electric | 
| UNSPSC: | 39121521 | 
| UPC: | 00785901103493 | 
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$154.27 /  Each
Typical price:$178.20 / Each
Quantity: 
- Schneider Electric Square D Manual Starter, Circuit Breaker Thermal Magnetic, Series: TeSys GV2RT, 690 V AC, 2.5 A, 50/60 Hz Frequency, 0.37/0.75/1.1/1.5 kW Motor, 3 Pole, Setting: 1.6 to 2.5 A, Manual Reset, 3 ph, Screw Clamp Connection, Class 10 Ambient Compensated Overload Relay, Rocker Lever Control, IP20 Enclosure, 100000 Cycles Operating Cycles, -20 to 60 deg C Operating, 89 mm H x 45 mm W x 78.5 in D DimensionsGV2RT07 ApplicationFood and Beverage, Material Working, Material Handling, Small Pumps and PackagingGV2RT07 Item Features- Manual and local control, when the motor circuit-breaker is used on its own and automatic and remote control when combined with a contactor
- Motor protection provided by thermal magnetic devices built into the circuit breaker
- No live parts are accessible to direct finger contact
- The addition of an undervoltage trip enables the motor circuit breaker to be tripped if voltage is lost
- The addition of a shunt trip enables remote control of tripping
- The control for the open or enclosed motor circuit breaker can be locked in the "N/C" position using 3 padlocks
- The system manages motors and other electrical loads up to 40 hp
- Up to 20 modules and 1 bus coupler (up to 112 cm L)
- One click mounting on DIN rail and no need for control wiring on modules
- No auxiliary wiring required, thanks to full connectivity over fieldbus
- All adjustments and setting are digitized, no mechanical dials or dip switches
- Energy monitoring at load level
- Detect and solve issues before your machine stops
- Gain better insight to the operation and performance of the machine
- Decrease time to market, helping improve project profitability
- 0.37 kW at 220/230 VAC, 0.75 kW at 400/415 VAC, 0.75 kW at 440 VAC, 1.1 kW at 440/500 VAC, 1.5 kW at 690 VAC motor rating
- https://www.youtube.com/embed/YkQwgPFibOM
 GV2RT07 StandardsRoHS Compliant|IEC 60947-4-1|EN 60204|NF C 63-120|VDE 0113|CSA C22.2|IEC 60947-2|UL 508|NFC 63-650|IEC 60947-1|VDE 0660|NFC 79-130|EAC Certified|UL Listed|CCC Certified|CSA Certified|REACH Compliant|WEEE Compliant|Green Premium|ECCN: EAR99|PROP65: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.govSKU #2303892Part Number #GV2RT07UNSPSC39121521UPC00785901103493