Schneider Electric, LC1D50U7, Contactor, Standard, Series: D-Line LC1D, 240 VAC Coil, 80 A Maximum Load Current, 140/160 VA Inrush, 13/15 VA Hold-In Coil, 3 Pole, 50/60 Hz Frequency, 30 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 50 A at 600 VAC Contact, Power Factor: 0.75 Inrush, 0.3 Hold-In, Screw Clamp Connection, 4.69 Size, IP2X Enclosure, 6000000 Cycles Operating Cycles, -5 to 60 deg C Operating, Surface Mounting, 127 mm H x 75 mm W x 119 mm D D
Image Disclaimers Message
Schneider Electric, LC1D50U7, Contactor, Standard, Series: D-Line LC1D, 240 VAC Coil, 80 A Maximum Load Current, 140/160 VA Inrush, 13/15 VA Hold-In Coil, 3 Pole, 50/60 Hz Frequency, 30 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 50 A at 600 VAC Contact, Power Factor: 0.75 Inrush, 0.3 Hold-In, Screw Clamp Connection, 4.69 Size, IP2X Enclosure, 6000000 Cycles Operating Cycles, -5 to 60 deg C Operating, Surface Mounting, 127 mm H x 75 mm W x 119 mm D D
Schneider Electric, LC1D50U7, Contactor, Standard, Series: D-Line LC1D, 240 VAC Coil, 80 A Maximum Load Current, 140/160 VA Inrush, 13/15 VA Hold-In Coil, 3 Pole, 50/60 Hz Frequency, 30 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 50 A at 600 VAC Contact, Power Factor: 0.75 Inrush, 0.3 Hold-In, Screw Clamp Connection, 4.69 Size, IP2X Enclosure, 6000000 Cycles Operating Cycles, -5 to 60 deg C Operating, Surface Mounting, 127 mm H x 75 mm W x 119 mm D D
Part #:LC1D50U7
SKU #: 934539
Key Features
Part #:LC1D50U7
SKU #: 934539
Brand: Schneider Electric
Coil Power Rating: 13; 15, 140/160 VA Inrush, 13/15 VA Hold-In
Coil Voltage: 240 VAC
Contact Configuration: 3NO
Contact Rating: 50 A at 600 VAC
Dimensions: 127 mm H x 75 mm W x 119 mm D
- Without built-in bi-directional peak limiting diode suppressor coil technology
- 10 A at 140 deg F control circuit
- TeSys D contactors are available in 11 contactor ratings for the USA market for inductive motor applications from 9 up to 150 full-load amps and resistive loads up to 200 amps
- Designed to control and provide overload protection to motors rated up to 100 HP at 480 VAC or 125 HP at 600 VAC, TeSys D meets your needs for a majority of motor starter applications
- New TeSys D Green increase TeSys D range with a new electronic coil with up to 80% less consumption than TeSys D standard AC or DC coil
- TeSys D Green contactor associated with TeSys LR9D electronic overload relay reduces heat generation and energy consumption up to 50
- High-fault short circuit current ratings provide the flexibility to select any component, as long as it meets or exceeds the desired SCCR
- Eliminates the time-consuming process of selecting tested combinations through web sites and spreadsheets
- Simple to select the right product
- 3-pole and 4-pole contactor versions available
- All contactors include built-in auxiliary contacts
- All screw connections have IP20 finger-safe terminals with both North American and International terminal markings
- Easily installed accessories
Schneider Electric, LC1D50U7, Contactor, Standard, Series: D-Line LC1D, 240 VAC Coil, 80 A Maximum Load Current, 140/160 VA Inrush, 13/15 VA Hold-In Coil, 3 Pole, 50/60 Hz Frequency, 30 kW Wattage, Non-Reversing Contact, 3NO Contact Configuration, 1NO-1NC Auxiliary Contacts, 50 A at 600 VAC Contact, Power Factor: 0.75 Inrush, 0.3 Hold-In, Screw Clamp Connection, 4.69 Size, IP2X Enclosure, 6000000 Cycles Operating Cycles, -5 to 60 deg C Operating, Surface Mounting, 127 mm H x 75 mm W x 119 mm D D
Schneider Electric LC1D50U7, Contactor, LC1F, 240 VAC Coil, 10; 80 Maximum Load Current, 13; 15 Coil, 3 Pole, 50/60 Hz Frequency, 3.7; 9.6 Wattage, 3NO Contact Configuration, NO/NC Auxiliary Contacts, 4.69 Size, Screw Clamp Terminal, IP2x Enclosure, 3600 Cycles Operating Cycles, -4 to 60 , 60 to 70 with derating deg C Operating, Plate/Rail Mounting, 127 mm H x 75 mm W x 119 mm D Dimensions
Additional Description: SQD -LC1D50U7 3P OLD CONT 25KW 1NO 1NC 240VAC COIL
Catalog Description: IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 240VAC 60Hz coil, open