Part Number # LC1D80004P7
SKU # 2272699
Image Disclaimers Message
LC1D80004P7
Schneider Electric LC1D80004P7 Tesys D Iec Contactor
Part Number # LC1D80004P7
SKU # 2272699
$683.65 / Each
Schneider Electric LC1D80004P7 Key Features
Brand: | Schneider Electric |
---|---|
Part Number # : | LC1D80004P7 |
SKU #: | 2272699 |
Coil Power Rating: | 245 VA Inrush, 26 VA Hold-In |
Coil Voltage: | 230, 230 VAC |
Contact Configuration: | 4NO |
Contact Rating: | 125 A at 575 VAC |
Dimensions: | 3.78 in W x 4.92 in D x 5 in H |
Enclosure Type: | Open |
Frequency Rating: | 50/60, 50/60 Hz |
Number of Poles: | 4 |
Operating Cycles: | 4000000, 4000000 Cycles |
Operating Temperature: | -23 to 140, -23 to 140 deg F |
Terminal Type: | Screw Clamp |
Type: | LC1D D-Line |
Wattage: | 12.5, 12.5 W |
Country of origin: | CZ |
Mounting type: | Surface |
Manufacturer Name: | Schneider Electric |
UNSPSC: | 39121529 |
UPC: | 00785901606680 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$683.65 / Each
Quantity:
- Schneider Electric TeSys D IEC Contactor, LC1D D-Line, 230 VAC Coil, 125 A Maximum Load Current, 245 VA Inrush, 26 VA Hold-In Coil, 4 Pole, 50/60 Hz Frequency, 12.5 W Wattage, 4NO Contact Configuration, 125 A at 575 VAC Contact, Screw Clamp Terminal, Open Enclosure, 4000000 Cycles Operating Cycles, -23 to 140 deg F Operating, Surface Mounting, 3.78 in W x 4.92 in D x 5 in H Dimensions
LC1D80004P7 Application
Resistive Load ApplicationsLC1D80004P7 Item Features
- Conforming to IEC 60947 rated impulse withstand voltage
- III overvoltage category
- 125 A at 140 deg F power circuit conventional free air thermal current
- 1100 A at 440 V power circuit conforming to IEC 60947 IRMS rated making capacity
- 1100 A at 440 V power circuit conforming to IEC 60947 rated breaking capacity
- 160 A gG at 690 V coordination type 2-power circuit, 200 A gG at 690 V coordination type 1 power circuit associated fuse rating
- 0.8 MOhm at 50 Hz, Ith 125 A power circuit average impedance
- 1000 V power circuit conforming to IEC 60947-4-1/600 V power circuit certifications CSA/600 V power circuit certifications UL rated insulation voltage
- 20 to 35 ms closing, 6 to 20 ms opening operating time
- 3600 cycles/hr at 140 deg F operating rate
- Without built-in suppressor module coil technology
- 245 VA at 68 deg F 50/60 Hz inrush power
- 26 VA at 68 deg F 60 Hz hold-in power consumption
- 6 to 10 W heat dissipation
- TH protective treatment
- 3 degree of pollution
- -40 to 158 deg F permissible ambient air temperature around the device, -76 to 176 deg F storage temperature
- 9842.52 ft without derating in temperature operating altitude
- 1562 deg F conforming to IEC 60695-2-1 fire resistance
- V1 conforming to UL 94 flame rating
- https://www.youtube.com/embed/kW01lFljKgE
LC1D80004P7 Standards
RoHS Compliant|CSA C22.2 #14|EN/IEC 60947-4-1/60947-5-1|BV Certified|CCC Certified|DNV Approved|GL/LROS/DINA Certified|ECCN EAR99|PROP65: This product can expose you to chemicals including: Antimony oxide and Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65warnings.ca.govSKU #2272699Part Number #LC1D80004P7UNSPSC39121529UPC00785901606680