Part Number # LC2K0901G7
SKU # 2215112
Image Disclaimers Message
Brand: Schneider Electric
LC2K0901G7
Schneider Electric LC2K0901G7 Tesys K Iec Contactor
Part Number # LC2K0901G7
SKU # 2215112
$165.42 / Each
Schneider Electric LC2K0901G7 Key Features
Brand: | Schneider Electric |
---|---|
Part Number # : | LC2K0901G7 |
SKU #: | 2215112 |
Coil Power Rating: | 4, 4 kW |
Coil Voltage: | 120, 120 VAC |
Contact Configuration: | 3NO |
Contact Rating: | 9 A at 575 VAC |
Dimensions: | 3.54 in W x 2.24 in D x 2.28 in H |
Enclosure Type: | IP20 |
Frequency Rating: | 50/60, 50/60 Hz |
Number of Auxiliary Contacts: | 1NC |
Number of Poles: | 3 |
Operating Cycles: | 5000000, 5000000 Cycles |
Operating Temperature: | -13 to 122, -13 to 122 deg F |
Terminal Type: | Screw Clamp |
Type: | K-Line LC2K |
Country of origin: | FR |
Mounting type: | Surface |
Manufacturer Name: | Schneider Electric |
UNSPSC: | 39121529 |
UPC: | 00785901700777 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$165.42 / Each
Quantity:
- Schneider Electric TeSys K IEC Contactor, K-Line LC2K, 120 VAC Coil, 20 A Maximum Load Current, 4 kW Coil, 3 Pole, 50/60 Hz Frequency, Reversing Contact, 3NO Contact Configuration, 1NC Auxiliary Contacts, 9 A at 575 VAC Contact, Screw Clamp Terminal, IP20 Enclosure, 5000000 Cycles Operating Cycles, -13 to 122 deg F Operating, Surface Mounting, 3.54 in W x 2.24 in D x 2.28 in H Dimensions
LC2K0901G7 Application
For motor control and resistive loadsLC2K0901G7 Item Features
- 8 kV rated impulse withstand voltage
- III overvoltage category
- 20 A at 122 deg F power circuit, 10 A at 122 deg F signaling circuit conventional free air thermal current
- 25 A gG at 440 V power circuit, 25 A aM power circuit, 10 A gG signaling circuit conforming to IEC 60947, 10 A gG signaling circuit conforming to VDE 0660 associated fuse rating
- 3 MOhm at 50 Hz, Ith 20 A power circuit average impedance
- Mechanical interlock
- 1.3 N-m on screw clamp terminals with screwdriver Philips No 2/flat 6 mm Dia tightening torque
- 10 to 20 ms coil de-energization and NO opening, coil energization and NO closing operating time
- 3600 cycles/hr operating rate
- 30 VA at 68 deg F inrush power
- 4.5 VA at 68 deg F hold-in power consumption
- 1.3 W heat dissipation
- 400 Hz signaling circuit frequency
- 5 mA minimum switching current
- 17 VAC signaling circuit minimum switching voltage
- 0.02 in non-overlap distance
- >10 MOhm signaling circuit insulation resistance
- TC protective treatment
- 2000 m without derating in temperature operating altitude
- 4 kW at 380 to 415 VAC 50/60 Hz, 4 kW at 440 VAC 50/60 Hz, 4 kW at 480 VAC 50/60 Hz, 4 kW at 500 to 600 VAC 50/60 Hz power rating
LC2K0901G7 Standards
CB Scheme;CCC;UL;CSA;EAC;CE;UKCASKU #2215112Part Number #LC2K0901G7UNSPSC39121529UPC00785901700777