Part Number # XCSE73137
SKU # 2296494
Image Disclaimers Message
XCSE73137
Telemecanique XCSE73137, Series: XCSE, 220 to 240 V, 2NC+1NO Contact Configuration, 3 Pole, Terminal Connection, IP67 Enclosure, -13 to 104 deg F Operating, Metal, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 104 deg F Operating Temperature
Part Number # XCSE73137
SKU # 2296494
Telemecanique XCSE73137 Key Features
| Brand: | Telemecanique |
|---|---|
| Part Number # : | XCSE73137 |
| SKU #: | 2296494 |
| Connection type: | Terminal |
| Contact Configuration: | 2NC+1NO |
| Country of origin: | ID |
| Enclosure Type: | IP67 |
| Environmental Conditions: | -40 to 158 deg F Storage Temperature, -13 to 104 deg F Operating Temperature |
| Material: | Metal |
| Number of Poles: | 3 |
| Operating Temperature: | -13 to 104 deg F |
| Series: | XCSE |
| Manufacturer Name: | YAGEO Corporation |
| UNSPSC: | 39122213 |
| UPC: | 03389110708783 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Telemecanique XCSE73137, Series: XCSE, 220 to 240 V, 2NC+1NO Contact Configuration, 3 Pole, Terminal Connection, IP67 Enclosure, -13 to 104 deg F Operating, Metal, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 104 deg F Operating Temperature
Brand: Telemecanique
Part Number: XCSE73137
Telemecanique XCSE73137, Series: XCSE, 220 to 240 V, 2NC+1NO Contact Configuration, 3 Pole, Terminal Connection, IP67 Enclosure, -13 to 104 deg F Operating, Metal, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 104 deg F Operating Temperature
Additional Description: TELE-XCSE73137 Safety Interlock
Catalog Description: This product is part of the XCS range, an offer of safety switches. The limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 normally closed + 1 normally opened, slow break contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 1.5A at 240V AC, 3A at 120V AC, 0.27A at 250V DC, 0.55 at 125V DC and a conventional enclosed thermal current of 6A. It is designed to operate in hazardous environments. It is furnished with screw clamp terminals for electrical connection and 2 cable entry tapped for 1/2inch NPT cable gland. The electromagnet interlocking on de-energization and unlocking on energization of solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP67 rated product. The key operated turret head limit switch has a rectangular metal body which is made of Zamak. Its dimensions are 98mm (Width) x 44mm (Depth) x 146mm (Height) and
XCSE73137 Application
For the protection of operators, by controlling the safe opening and interlocking of guards and covers, For electrical connection and 2 cable entry tapped for 1/2inch NPT cable glandXCSE73137 Item Features
- Rectangular design
- 2 entries tapped 1/2" NPT cable entry
- Locking on de-energisation and unlocking on energisation of solenoid electromagnet interlocking
- 24 V - 20 to 10 % us solenoid rated supply voltage
- 24/48 V 20 to 52 V signalling circuit voltage
- With NC contact positive opening
- 1 load factor
- AC/DC signalling circuit type
- 7 mA signalling circuit consumption
- 1000000 cycles mechanical durability
- 03 ft/s 01 m/s minimum actuation speed
- 1.64 ft/s 0.5 m/s maximum actuation speed
- 50 VEN/IEC 60947-1 signalling circuit ui rated insulation voltage
- 6 kV EN/IEC 60947-5-1 uimp rated impulse withstand voltage
- Overvoltage protection signalling circuit protection type
- 10 A cartridge fuse gG gl short-circuit protection
- 2000 N actuator forcible withdrawal rtc
- 20 N minimum actuator force for extraction
- Zamak body material
XCSE73137 Standards
CSA|UL Listed|PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov|UL 508EN 1088/ISO 14119EN/ISO 12100|EN/IEC 60947-5-1CSA C22.2 No 14|EN/IEC 60204-1SKU #2296494Part Number #XCSE73137UNSPSC39122213UPC03389110708783