Part Number # XS8G12MA230
SKU # 968954

Brand: Telemecanique
XS8G12MA230
Telemecanique XS8G12MA230 Osisense Xs Proximity Sensor
Part Number # XS8G12MA230
SKU # 968954
$96.00 / Each
Telemecanique XS8G12MA230 Key Features
| Brand: | Telemecanique |
|---|---|
| Part Number # : | XS8G12MA230 |
| SKU #: | 968954 |
| Amperage Rating: | 5 to 200 mA |
| Environmental Conditions: | 25 gn Amplitude Vibration/50 gn 11 ms Shock Resistance |
| Frequency Response: | 50/60/250 Hz |
| Response Time: | 1 ms |
| Sensing Distance: | 0.1 to 0.16 in |
| Sensing Method: | Inductive |
| Sensing Position: | Lateral |
| Series: | XS8 |
| Size: | 0.47 in W x 1.02 in D x 1.57 in H |
| Mounting type: | Non-Flush |
| UNSPSC: | 39122230 |
| UPC: | 00785901776727 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$96.00 / Each
Quantity:
- Telemecanique OsiSense XS Proximity Sensor, Fixed, Series: XS8, Inductive Sensing Method, 0.1 to 0.16 in Sensing Distance, Lateral Sensing Position, 1NO Contact Configuration, 24 to 240 V AC/DC, 5 to 200 mA, 50/60/250 Hz Frequency Response, Cable Connection, 1 ms Response, 0.47 in W x 1.02 in D x 1.57 in H Size, IP67 Enclosure, -25 to 70 deg C, Non-Flush Mounting, Plastic, Environmental Conditions: 25 gn Amplitude Vibration/50 gn 11 ms Shock Resistance
XS8G12MA230 Specifications
- Lateral detection face
- <=40 ms delay first up
- <=1 ms delay response
- <=2 ms delay recovery
- 25 gn amplitude is /-2 mm, conforming to IEC 60068-2-6 vibration resistance
- 50 gn for 11 ms conforming to EN 60068-2-27 Shock resistance
- Discrete type of output signal
- 5 to 200 mA switching capacity
- Plastic enclosure/front/PVC wire insulation
- 2 m cable connection
- Non-flush mounting
- 2 wire configuration
- 0 to 3.2 mm operating zone
- 3 to 20% of Sr differential travel
- 2 x 0.34 sq-mm cable composition
- 1 LED yellow for output state status LED
- 20 to 264 VAC/VDC supply voltage limits
- <=25 Hz AC, <=250 Hz DC switching frequency
- <=5.5 V closed state voltage drop
XS8G12MA230 Application
General Purpose ApplicationsXS8G12MA230 Standards
RoHS Compliant|CCC Certified|CE Marked|CSA Certified|UL Listed|PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.govSKU #968954Part Number #XS8G12MA230UNSPSC39122230UPC00785901776727
Image provided may only be a representation of final product and may include optional equipment