Part Number # XUX0ARCTT16T
SKU # 2194773
Image Disclaimers Message
XUX0ARCTT16T
Telemecanique XUX0ARCTT16T Osisense Photoelectric Sensor
Part Number # XUX0ARCTT16T
SKU # 2194773
Telemecanique XUX0ARCTT16T Key Features
Brand: | Telemecanique |
---|---|
Part Number # : | XUX0ARCTT16T |
SKU #: | 2194773 |
Amperage Rating: | 3, 3 A |
Enclosure Type: | IP65/IP67 |
Environmental Conditions: | -40 to 158 deg F Storage Temperature, 30 gn 11 ms Shock Resistance/Corrosion Resistant (Indoor)/Dust Tight/Oiltight/Watertight |
Frequency Rating: | 20, 20 Hz, <=20 |
Light Source: | Infrared, LED |
Operating Temperature: | -13 to 131, -13 to 131 deg F |
Response Time: | 25, 25 ms, <25 |
Sensing Beam: | Infrared, Through Beam |
Sensing Method: | Photoelectric, Through Beam, Thru-Beam |
Sensing Range: | 196.85, 60, 60 m |
Series: | XU Series |
Size: | 1.22 in W x 3.03 in D x 3.62 in H, 3.62 in H x 1.22 in W x 3.03 in D |
Type: | Compact Multi-Mode |
Vibration: | 7, 7 gn |
Connection type: | Cable, Screw Clamp |
Country of origin: | FR |
Manufacturer Name: | YAGEO Corporation |
UNSPSC: | 39121528 |
UPC: | 00785901501268 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Telemecanique XUX0ARCTT16T Osisense Photoelectric Sensor
Brand: Telemecanique
Part Number: XUX0ARCTT16T
Telemecanique OsiSense Photoelectric Sensor, Compact Multi-Mode, Thru-Beam Sensing Method, 60 m Sensing, Infrared Sensing Beam, 25 ms Response, 24 to 240 VAC/VDC, 3 A, 20 Hz Frequency, Screw Clamp Connection, LED Light Source, 7 gn Vibration, 1.22 in W x 3.03 in D x 3.62 in H Size, IP65/IP67 Enclosure, -13 to 131 deg F Operating, Environmental Conditions: 30 gn 11 ms Shock Resistance/Corrosion Resistant (Indoor)/Dust Tight/Oiltight/Watertight
Additional Description: TELE-XUX0ARCTT16T PHOTOELECTRIC SENSOR COMPACT EMITTER XUX 11-2
Catalog Description: This compact design multi mode photo-electric transmitter has a PBT case. It has a supply voltage of 24V to 240V AC/DC. This multi-mode rectangular photoelectric emitter has a painted aluminium and polyamide construction, is mountable directly on a surface or bracket, thanks to its 4 fixing points. It has VALOX® PBT high strength case ideal for high temperature environments and PMMA scratch-resistant lens for maximum sensor durability. 2 LED display allows to identify status of the sensor and beam instability, to facilitate troubleshooting. IP65 and IP67 protection makes this product ready for the harshest environments. It can operate in very cold (-25°C) and hot environments (+55°C). It provides double insulation for better people and system protection from electrical shocks. It is CSA and UL certified.
XUX0ARCTT16T Specifications
- Compact 92 x 71 sensor design
- 0.5 A (cos f =0.4 for 0.5 million cycles at 1 operating cycles per second at 250 V), 3 A (cos f =1 for 0.5 million cycles at 1 operating cycles per second at 250 V) switching capacity
- 20 mA (no-load) current consumption
- <200 ms delay first up
- <25 ms delay response
- <25 ms delay recovery
- Without sensitivity adjustment setting-up
- 0.4, 500 cycles/min 500000 cycles, cos f, 1, 3000 cycles/min 500000 cycles, cos f electrical durability
- 7 gn, amplitude =+/-1.5 mm (10 to 55 Hz) conforming to IEC 60068-2-6 vibration resistance
- 30 gn (duration = 11 ms) conforming to IEC 60068-2-27 shock resistance
- 1 entry for M16 x 1.5 cable gland, 0.28 to 0.39 in cable outer Dia cable entry
- Thru beam detection system
- 131.23 ft (40 m) thru beam need a receiver nominal sensing distance
- Plastic material
- 3 wire configuration
- PBT enclosure material, PMMA lens material
- Test by emission breaking add on input
- <=1.5 V closed state voltage drop
- (1) LED (green) supply on LED status
- 20 to 264 VAC/VDC supply voltage limits
XUX0ARCTT16T Application
General Purpose ApplicationsXUX0ARCTT16T Standards
BAA Compliant|RoHS Compliant|CE Certified|CSA Certified|UL File #E164869 CCN NRKH|PROP65: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65warnings.ca.govSKU #2194773Part Number #XUX0ARCTT16TUNSPSC39121528UPC00785901501268