ABB XT2SE3160BFF000XXX Key Features
Brand: | ABB |
---|---|
Part Number # : | XT2SE3160BFF000XXX |
SKU #: | 2335204 |
Amperage Rating: | 160, 160 A |
Dimensions: | 5.12 in H x 3.54 in W x 3.25 in D |
Frame: | XT2 125 A, XT2 125A |
Frequency Rating: | 50/60, 50/60 Hz |
Interrupt Rating: | 22, 22 kA |
Number of Poles: | 3 |
Series: | Tmax XT |
Temperature Rating (Degrees F): | -13 to 158, -13 to 158 deg F |
Trip Range: | 160 to 1600, 160 to 1600 A |
Trip Type: | Adjustable/Thermal Magnetic/Electronic, Electronic |
Type: | Low Voltage |
Connection type: | Front Line/Load Side |
Country of origin: | IT |
Manufacturer Name: | ABB |
UNSPSC: | 39121616 |
UPC: | 00888614446175 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
$3622.48 / Each
Quantity:
- ABB Molded Case Circuit Breaker, Low Voltage, Series: Tmax XT, 600/690 VAC, 160 A, 50/60 Hz Frequency, 22 kA Interrupt, XT2 125A Frame, Electronic Trip, 160 to 1600 A Trip, 3 Pole, Front Line/Load Side Connection, Double Insulated Insulation, -13 to 158 deg F, 5.12 in H x 3.54 in W x 3.25 in D Dimensions
XT2SE3160BFF000XXX Specifications
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
- F front terminals, no lugs installed on line and load side termination (top/bottom)
- 22 kA standard breaking capacity
XT2SE3160BFF000XXX Application
For all distribution levels from the main low voltage switchboard to the sub-switchboards in the installationXT2SE3160BFF000XXX Item Features
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
- F front terminals, no lugs installed on line and load side termination (top/bottom)
- 22 kA standard breaking capacity
XT2SE3160BFF000XXX Standards
UL Listed|CSA Certified|IEC CertifiedSKU #2335204Part Number #XT2SE3160BFF000XXXUNSPSC39121616UPC00888614446175