XT2SE3160BFF000XXX
ABB XT2SE3160BFF000XXX
Part Number # XT2SE3160BFF000XXX
SKU # 2335204
$3622.48 / Each
ABB XT2SE3160BFF000XXX Key Features
| Brand: | ABB |
|---|---|
| Part Number # : | XT2SE3160BFF000XXX |
| SKU #: | 2335204 |
| Trip Range: | 160 to 1600 A |
| UNSPSC: | 39121616 |
| UPC: | 00888614446175 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Prices are in USD. Orders shipped to Canada may be subject to duties, taxes and brokerage fees, collected by the carrier on delivery.
$3622.48 / Each
Quantity:
ABB XT2SE3160BFF000XXX
Brand: ABB
Part Number: XT2SE3160BFF000XXX
Additional Description: ABB -XT2SE3160BFF000XXX (N) XT2S 160 TMA 160-1600 3P F F NON-CANCELABLE, NON-RETURNABLE
XT2SE3160BFF000XXX Specifications
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
- F front terminals, no lugs installed on line and load side termination (top/bottom)
- 22 kA standard breaking capacity
XT2SE3160BFF000XXX Application
For all distribution levels from the main low voltage switchboard to the sub-switchboards in the installationXT2SE3160BFF000XXX Item Features
- Feature high specific let-through current peak and energy limiting characteristics that allow the circuits and equipment on the load side to be sized in optimum way
- XTraordinary limiting characteristics allow savings in copper and footprint in switchboard, high selectivity values and very compact motor protection solutions high breaking capacity
- A dedicated range of accessories and a renewed solution for electronic trip units to adapt Tmax XT to different applications scenarios installation flexibility
- Specific electronic trip units for energy metering, motor protection and generator protection in addition to a Modbus communication module for integration in a supervision system
- Wide range of keylocks and padlocking options, plug-in and withdrawable versions to speed up maintenance operations and improved diagnostic to have ready to use information about breakers status
- Frame XT2 to 125 A, 600 V (UL)/160 A (IEC), 690 V thermal magnetic and electronic protection
- F front terminals, no lugs installed on line and load side termination (top/bottom)
- 22 kA standard breaking capacity
XT2SE3160BFF000XXX Standards
UL Listed|CSA Certified|IEC CertifiedSKU #2335204Part Number #XT2SE3160BFF000XXXUNSPSC39121616UPC00888614446175
Image provided may only be a representation of final product and may include optional equipment