Part Number # FD63B125L
SKU # 2183384
Image provided may only be a representation of
final product and may include optional equipment
FD63B125L
Siemens FD63B125L Sentron Molded Case Circuit Breaker
Part Number # FD63B125L
SKU # 2183384
Siemens FD63B125L Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | FD63B125L |
| SKU #: | 2183384 |
| Amperage Rating: | 125 A |
| Dimensions: | 7 in L x 6 in W x 11 in H |
| Frame: | FD |
| Frequency Rating: | 50/60, 50/60 Hz |
| Interrupt Rating: | 22, 22 kA |
| Number of Poles: | 3 |
| Phase: | 3 |
| Temperature Rating (Degrees F): | 40, 40 deg C |
| Trip Range: | 900 to 1500, 900 to 1500 A |
| Trip Type: | Thermal Magnetic, Thermal/Magnetic |
| Type: | Type FD6 Low Voltage |
| Connection type: | Line/Load Lug |
| Country of origin: | MX |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121601 |
| UPC: | 00783643005303 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens FD63B125L Sentron Molded Case Circuit Breaker
Brand: Siemens
Part Number: FD63B125L
Siemens Sentron Molded Case Circuit Breaker, Type FD6 Low Voltage, 600 VAC/500 VDC, 125 A, 50/60 Hz Frequency, 22 kA Interrupt, FD Frame, Thermal/Magnetic Trip, 900 to 1500 A Trip, 3 Pole, 3 ph, Line/Load Lug Connection, 40 deg C, 7 in L x 6 in W x 11 in H Dimensions
Additional Description: SIEM-FD63B125L (N) BRKR FD6 3P 600V 125A LUG LUGS LUGS ASSY LUGS NON-CANCELABLE, NON-RETURNABLE
Catalog Description: SIEMENS LOW VOLTAGE SENTRON MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETICTRIP UNIT. ASSEMBLED STANDARD 40 DEG C BREAKER FD FRAME WITH STANDARD BREAKING CAPACITY. 125A 3-POLE (22KAIC AT 600V) (35KAIC AT 480V). INTERCHANGEABLE TRIP UNIT. SPECIAL FEATURES LINE AND LOAD SIDE LUGS (TA1FD350A) WIRE RANGE 6AWG - 350KCMIL (CU) / 4AWG - 350KCMIL (AL). DIMENSIONS (W x H x D) IN 4.50 x 9.5 x 4.00.
FD63B125L Application
Standard 40C Breaker ApplicationsFD63B125L Item Features
- Molded case circuit breakers are used in motor circuits as a disconnecting means and for short circuit protection
- They should be used in conjunction with motor running, over-current-protection devices and should permit the motor to start without nuisance tripping from motor-inrush current
- The circuit breaker should have a continuous current rating of not less than 115% of the motor full load current
- Actuator varying
- Enclosure varying
- Blue label
FD63B125L Standards
UL/HACRSKU #2183384Part Number #FD63B125LUNSPSC39121601UPC00783643005303

