Part Number # FXD63A150
SKU # 19981
Image provided may only be a representation of
final product and may include optional equipment
FXD63A150
Siemens FXD63A150 Sentron Molded Case Circuit Breaker
Part Number # FXD63A150
SKU # 19981
Siemens FXD63A150 Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | FXD63A150 |
| SKU #: | 19981 |
| Amperage Rating: | 150, 150 A |
| Dimensions: | 7 in L x 5.4 in W x 10.9 in H |
| Frame: | FD |
| Frequency Rating: | 50/60, 50/60 Hz |
| Interrupt Rating: | 22, 22 kA |
| Number of Poles: | 3 |
| Phase: | 3 |
| Temperature Rating (Degrees F): | 40, 40 deg C |
| Trip Range: | 800 to 1500, 800 to 1500 A |
| Trip Type: | Thermal Magnetic, Thermal/Magnetic |
| Type: | Type FXD6 Low Voltage |
| Connection type: | Bolt-On |
| Country of origin: | MX |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121601 |
| UPC: | 00783643212275 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens FXD63A150 Sentron Molded Case Circuit Breaker
Brand: Siemens
Part Number: FXD63A150
Siemens Sentron Molded Case Circuit Breaker, Type FXD6 Low Voltage, 600 VAC, 150 A, 50/60 Hz Frequency, 22 kA Interrupt, FD Frame, Thermal/Magnetic Trip, 800 to 1500 A Trip, 3 Pole, 3 ph, Bolt-On Connection, 40 deg C, 7 in L x 5.4 in W x 10.9 in H Dimensions
Additional Description: SIEM-FXD63A150 (N) BREAKER FD 3P 150A 600V 22KA ETI NON-CANCELABLE, NON-RETURNABLE
Catalog Description: SIEMENS LOW VOLTAGE SENTRON MOLDED CASE CIRCUIT BREAKER WITH MAGNETIC TRIP ONLYUNIT. STANDARD RANGE ETI BREAKER FD FRAME WITH STAND ARDBREAKING CAPACITY AND NON INTERCHANGEABLE TRIP. MEETS UL 489 / IEC60947-2 STANDARDS. 150A 3-POLE BREAKER (22KAIC AT 600V) (35KAIC AT480V). SPECIAL FEATURES NO LUGS INSTALLED. DIMENSIONS (W x H x D) IN 4.5 x 9.5 x 4._____________________________________________ ___________________________
FXD63A150 Application
For standard range ETI breakerFXD63A150 Item Features
- Molded case circuit breakers are used in motor circuits as a disconnecting means and for short circuit protection
- They should be used in conjunction with motor running, over-current-protection devices and should permit the motor to start without nuisance tripping from motor-inrush current
- The circuit breaker should have a continuous current rating of not less than 115% of the motor full load current
- Varying actuator
- Varying enclosure
- Blue label
- Standard range ETI breaker
FXD63A150 Standards
HACR Rated|UL 489SKU #19981Part Number #FXD63A150UNSPSC39121601UPC00783643212275