Part Number # FXD63B200L
SKU # 19990
FXD63B200L
Siemens FXD63B200L Sentron Molded Case Circuit Breaker
Part Number # FXD63B200L
SKU # 19990
Siemens FXD63B200L Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | FXD63B200L |
| SKU #: | 19990 |
| Amperage Rating: | 200, 200 A |
| Dimensions: | 6.9 in L x 5.5 in W x 11.1 in H |
| Frame: | FD |
| Frequency Rating: | 50/60, 50/60 Hz |
| Interrupt Rating: | 22, 22 kA |
| Number of Poles: | 3 |
| Phase: | 3 |
| Temperature Rating (Degrees F): | 40, 40 deg C |
| Trip Range: | 900 to 2000, 900 to 2000 A |
| Trip Type: | Thermal Magnetic, Thermal/Magnetic |
| Type: | Type FXD6 Low Voltage |
| Connection type: | Line/Load Lug |
| Country of origin: | MX |
| Mounting type: | Freestanding |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121601 |
| UPC: | 00783643006003 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens FXD63B200L Sentron Molded Case Circuit Breaker
Brand: Siemens
Part Number: FXD63B200L
Siemens Sentron Molded Case Circuit Breaker, Type FXD6 Low Voltage, 600 VAC, 200 A, 50/60 Hz Frequency, 22 kA Interrupt, FD Frame, Thermal/Magnetic Trip, 900 to 2000 A Trip, 3 Pole, 3 ph, Line/Load Lug Connection, Freestanding Mounting, 40 deg C, 6.9 in L x 5.5 in W x 11.1 in H Dimensions
Additional Description: SIEM-FXD63B200L BRKR FD6 3P 600V 200A FX LUG LUGS
Catalog Description: SIEMENS LOW VOLTAGE SENTRON MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETICTRIP UNIT. ASSEMBLED STANDARD 40 DEG C BREAKER FD FRAME WITH STANDARD BREAKING CAPACITY. 200A 3-POLE (22KAIC AT 600V) (35KAIC AT 480V). NON-INTERCHANGEABLE TRIP UNIT. SPECIAL FEATURES LINE AND LOAD SIDE LUGS (TA1FD350A) WIRE RANGE 6AWG - 350KCMIL (CU) / 4AWG - 350KCMIL (AL). DIMENSIONS (W x H x D) IN 4.50 x 9.5 x 4.00.
FXD63B200L Application
Standard 40C Breaker ApplicationsFXD63B200L Item Features
- Molded case circuit breakers are used in motor circuits as a disconnecting means and for short circuit protection
- They should be used in conjunction with motor running, over-current-protection devices and should permit the motor to start without nuisance tripping from motor-inrush current
- The circuit breaker should have a continuous current rating of not less than 115% of the motor full load current
- Varying actuator
- Varying enclosure
- Blue label
FXD63B200L Standards
HACRSKU #19990Part Number #FXD63B200LUNSPSC39121601UPC00783643006003
Image provided may only be a representation of final product and may include optional equipment