Siemens MT0075C Key Features
Brand: Siemens
Part Number # MT0075C
SKU #2244818
Dimensions: 3.46 in H x 3 in W x 4.1 in D
Enclosure Type: IP20
Frequency Rating: 50/60, 50/60 Hz
Insulation: Epoxy
Maximum Amperage Rating: 0.29, 0.29 A
Phase: 1
Power Rating: 75, 75 VA
Primary Voltage: 120/240, 120/240 VAC
Secondary Voltage: 24, 24 VAC
Temperature Rating (Degrees F): 55, 55 deg C
Type: Class MT
Connection type: Screw
Country of origin: MX
Mounting type: Slotted
Manufacturer Name: Siemens
UNSPSC: 39121026
UPC: 00754554026725
$102.54 / Each
Siemens MT0075C Control Power Transformer
Brand: Siemens
Part Number: MT0075C
Siemens Control Power Transformer, Class MT, 120/240 VAC Primary, 24 VAC Secondary, 75 VA Power, 50/60 Hz Frequency, 1 ph, 0.29 A Maximum, Screw Connection, Slotted Mounting, Epoxy Insulation, IP20 Enclosure, 55 deg C, 3.46 in H x 3 in W x 4.1 in D Dimensions
Additional Description: SIEM-MT0075C CONTROL TRANSFORMER,75VA,120/240-24V, TRANSFORMER,75VA,120/240-24V
Catalog Description: Control Power Transformer, 75va, PRI 120x240v, SEC 24v, Domestic
MT0075C Application
For domestic usageMT0075C Item Features
- Epoxy encapsulated (50 to 750 VA), epoxy resin impregnated (1 to 5 kVA)
- Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
- Fuse clips (most models), factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add-on fuse block or kit
- Integrally molded barriers, between terminals and transformer, protect against electrical creepage, up to 30% greater terminal contact area permits low loss connections, extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
- Terminals, molded into the transformer, are difficult to break during wiring, a full quarter-inch of thread on the #10-32 terminal screws prevents stripping and pullout
- Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
- Laminations are built with silicon steel to minimize core losses and to increase optimum performance and efficiency
- Insulation materials are of the highest rating available for the temperature class
- Robust design
- 0.29 A max at 240 VAC
MT0075C Standards
cUL Listed|UL Listed|CSA Certified|ANSI SpecifiedSKU #2244818Part Number #MT0075CUNSPSC39121026UPC00754554026725