Part Number # MT0075I
SKU # 2364320
Image provided may only be a representation of
final product and may include optional equipment
MT0075I
Siemens MT0075I Control Power Transformer
Part Number # MT0075I
SKU # 2364320
Siemens MT0075I Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | MT0075I |
| SKU #: | 2364320 |
| Dimensions: | 2.79 in H x 3 in W x 3.78 in D |
| Enclosure Type: | IP20 |
| Frequency Rating: | 50/60, 50/60 Hz |
| Insulation: | Class 130 deg C |
| Phase: | 1 |
| Primary Voltage: | 380/400/415, 380/400/415 V AC, 380/400/415 VAC |
| Secondary Voltage: | 110 x 220, 110 x 220 V AC, 110 x 220 VAC |
| Temperature Rating (Degrees F): | 55, 55 deg C |
| Type: | Class MT |
| Connection type: | Screw Terminal |
| Country of origin: | MX |
| Mounting type: | Slotted |
| Power factor: | 20, 20 %, 20% |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121026 |
| UPC: | 00754554026787 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens MT0075I Control Power Transformer
Brand: Siemens
Part Number: MT0075I
Siemens Control Power Transformer, Class MT, 380/400/415 VAC Primary, 110 x 220 VAC Secondary, 75 VA Power, 50/60 Hz Frequency, 1 ph, Power Factor: 20 %, Screw Terminal Connection, Slotted Mounting, Class 130 deg C Insulation, IP20 Enclosure, 55 deg C, 2.79 in H x 3 in W x 3.78 in D Dimensions
Additional Description: SIEM-MT0075I CONTROL TRANSFORMER,75VA,380/400/415-110
Catalog Description: Control Power Transformer, 75va, PRI 380/400/415v, SEC 110x220v, Domestic
MT0075I Application
Domestic ApplicationsMT0075I Includes
JumperMT0075I Item Features
- Enclosed coils, completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
- Fuse clips, factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add on fuse block or kit
- Integrally finger-safe terminals, between terminals and transformer, protect against electrical creepage
- Up to 30% greater terminal contact area permits low loss connections
- Extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
- Terminals molded into the transformer are difficult to break during wiring
- A full quarter-inch of thread on the 8-32 terminal screws prevents stripping and pullout
- Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
- Integrally molded barriers
MT0075I Standards
UL Listed|cUL Listed|ANSI Specified|CSA CertifiedSKU #2364320Part Number #MT0075IUNSPSC39121026UPC00754554026787

