Part Number # MT0200F
SKU # 2357071
MT0200F
Siemens MT0200F Control Power Transformer
Part Number # MT0200F
SKU # 2357071
Siemens MT0200F Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | MT0200F |
| SKU #: | 2357071 |
| Dimensions: | 4.46 in H x 4.5 in W x 4.32 in D |
| Enclosure Type: | IP20 |
| Frequency Rating: | 50/60, 50/60 Hz |
| Insulation: | Class 130 deg C |
| Phase: | 1 |
| Primary Voltage: | 208/277, 208/277 V AC, 208/277 VAC |
| Secondary Voltage: | 120, 120 V AC, 120 VAC |
| Temperature Rating (Degrees F): | 55, 55 deg C |
| Type: | Class MT |
| Connection type: | Screw Terminal |
| Country of origin: | MX |
| Mounting type: | Slotted |
| Power factor: | 20, 20 %, 20% |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121026 |
| UPC: | 00754554027050 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens MT0200F Control Power Transformer
Brand: Siemens
Part Number: MT0200F
Siemens Control Power Transformer, Class MT, 208/277 VAC Primary, 120 VAC Secondary, 200 VA Power, 50/60 Hz Frequency, 1 ph, Power Factor: 20 %, Screw Terminal Connection, Slotted Mounting, Class 130 deg C Insulation, IP20 Enclosure, 55 deg C, 4.46 in H x 4.5 in W x 4.32 in D Dimensions
Additional Description: SIEM-MT0200F CONTROL TRANSFORMER,200VA,208/277-120V,
Catalog Description: Control Power Transformer, 200va, PRI 208/277v, SEC 120v, Domestic
MT0200F Application
Domestic ApplicationsMT0200F Includes
JumperMT0200F Item Features
- Enclosed coils, completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
- Fuse clips, factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add on fuse block or kit
- Integrally finger-safe terminals, between terminals and transformer, protect against electrical creepage
- Up to 30% greater terminal contact area permits low loss connections
- Extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
- Terminals molded into the transformer are difficult to break during wiring
- A full quarter-inch of thread on the 8-32 terminal screws prevents stripping and pullout
- Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
- Integrally molded barriers
MT0200F Standards
UL Listed|cUL Listed|ANSI Specified|CSA CertifiedSKU #2357071Part Number #MT0200FUNSPSC39121026UPC00754554027050
Image provided may only be a representation of final product and may include optional equipment

