Part Number # MT0350D
SKU # 2346420
MT0350D
Siemens MT0350D Control Power Transformer
Part Number # MT0350D
SKU # 2346420
Siemens MT0350D Key Features
| Brand: | Siemens |
|---|---|
| Part Number # : | MT0350D |
| SKU #: | 2346420 |
| Dimensions: | 4.47 in H x 4.5 in W x 5.6 in D |
| Enclosure Type: | Open |
| Frequency Rating: | 50/60, 50/60 Hz |
| Insulation: | Class 130 deg C |
| Phase: | 1 |
| Primary Voltage: | 115 x 230, 115 x 230 V AC, 115 x 230 VAC |
| Secondary Voltage: | 24, 24 V AC, 24 VAC |
| Temperature Rating (Degrees F): | -4 to 104, -4 to 104 deg F |
| Type: | Class MT |
| Connection type: | Screw Terminal |
| Country of origin: | MX |
| Mounting type: | Surface |
| Power factor: | 20, 20 %, 20% |
| Manufacturer Name: | Siemens |
| UNSPSC: | 39121026 |
| UPC: | 00754554027333 |
Buy Now Pay Later
Get 30 days to pay with Net 30 Terms. Apply Now.
Siemens MT0350D Control Power Transformer
Brand: Siemens
Part Number: MT0350D
Siemens Control Power Transformer, Class MT, 115 x 230 VAC Primary, 24 VAC Secondary, 350 VA Power, 50/60 Hz Frequency, 1 ph, Power Factor: 20 %, Screw Terminal Connection, Surface Mounting, Class 130 deg C Insulation, Open Enclosure, -4 to 104 deg F, 4.47 in H x 4.5 in W x 5.6 in D Dimensions
Additional Description: SIEM-MT0350D CONTROL TRANSFORMER,350VA,115/230-24V,
Catalog Description: Control Power Transformer, 350va, PRI 115x230v, SEC 24v, Domestic
MT0350D Application
Domestic ApplicationsMT0350D Item Features
- Enclosed coils, completely encloses the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
- Fuse clips, factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add on fuse block or kit
- Integrally finger-safe terminals, between terminals and transformer, protect against electrical creepage
- Up to 30% greater terminal contact area permits low loss connections
- Extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
- Terminals molded into the transformer are difficult to break during wiring
- A full quarter-inch of thread on the 8-32 terminal screws prevents stripping and pullout
- Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
MT0350D Standards
UL Listed|cUL Listed|ANSI Specified|CSA CertifiedSKU #2346420Part Number #MT0350DUNSPSC39121026UPC00754554027333
Image provided may only be a representation of final product and may include optional equipment